background image

             Issue Date: 10-02-98        Rev. Date: 11-03-08        Rev. Level: 09        ECN N/A         OIPM P/N 3420308     Page 3 of 4 

  
 
 
 

 

SYMPTOM 

 

 

POSSIBLE CAUSE(S) 

 

 

CORRECTIVE ACTION 

Element does not energize. 
 
 
 
 
Not enough heat. 
 
 
Too much heat.

 

1.  Defective element. 
2.  Improper connection. 
 
3.  Pigtail loose from socket 
connection. 
1.  Heater too small for application. 
2.  Heater mounted too high or too far. 
 
1.  Heater too large for application. 
2.  Heater mounted too low or too 
close.

 

1.  Replace element. 
2.  Check connection to outlet. 
     Check power. 
3.  Rewind pigtail on socket. 
 
1.  Add additional heaters. 
2.  Decrease mounting height or 
distance. 
1.  Replace with smaller heater. 
2.  Increase mounting height or 
distance.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
"A" dimension indicates exact spacing  
between mounting brackets. (See sketch  
at right.)

 

 
 
 

 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 

 

REPLACEMENT PARTS LIST and EXPLODED VIEW 

TROUBLESHOOTING CHART 

 

Model

 

MM

 

-

 

13A

 

MM

 

-

 

18A

 

MM

 

-

 

24A

 

MM

 

-

 

33A

 

MM

 

-

 

46A

 

"A" Dim.

 

4"

 

9"

 

15"

 

24"

 

37”

 

2 1/2

A

Mounting brackets extend 1"
from the top of the end boxes.

Knockouts are 7/8" diameter to
accept 1/2" conduit.

 

4

 

 1

 

7

 

18

 

6

 

  5

 

11

 

9

 

2

 

   19

 

20

 

8

 

15

 

 14

 

3

 

10

 

16

 

3

 

  10

 

12

 

8

 

6

 

   7

 

9

 

11

 

MOUNTING DIMENSIONS 

 

 

 

Содержание MITEY MIDGET

Страница 1: ...EAKER AS DESCRIBED ABOVE FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC SHOCK 2 This heater is intended ONLY for permanent installation in accordance with the National Electric Code NEC all applicable local codes and ordinances and all sections of this manual Any variance voids the warranty and may create unsafe conditions All wiring should be done by a qualified electrician using copper wire onl...

Страница 2: ...provided from the terminal box through the customer provided conduit and connect the supply wiring inside the customer provided splice box See Figure 2 below 3 Follow local and national electric codes 4 Do not use the heater as a field wiring compartment WIRING 1 2 slack on pigtail Cut off excess Wrap pigtail clockwise around screw Figure 1 Splice box by cust 6 conduit nipple by customer Figure 2 ...

Страница 3: ...Replace element 2 Check connection to outlet Check power 3 Rewind pigtail on socket 1 Add additional heaters 2 Decrease mounting height or distance 1 Replace with smaller heater 2 Increase mounting height or distance A dimension indicates exact spacing between mounting brackets See sketch at right REPLACEMENT PARTS LIST and EXPLODED VIEW TROUBLESHOOTING CHART Model MM 13A MM 18A MM 24A MM 33A MM 4...

Страница 4: ...plicable heating or electrical codes and the manufacturer s installation instructions It further requires that he perform reasonable and necessary maintenance on the unit The company is not liable for abuse or misuse of product as may be finally determined by the company FOSTORIA INDUSTRIES INC 1200 North Main Street Fostoria Ohio 44830 1911 419 435 9201 WARRANTY REF NO 1 2 3 4 5 6 7 8 9 10 11 12 ...

Отзывы: