REQUIRED CLEARANCE 

Caution - Spacing: 

Heaters must be mounted a minimum 

of  24"  from  a  vertical  surface,  a  minimum  of  24"  from  the 
ceiling,  a  minimum  of  24"  from  direct  radiation  to 
combustibles,  and  a  minimum  of  2.4M  (7.87’)  above  the 
floor.  Heaters must be at least 36” apart. 

WARNING!

 

DO  NOT  ATTEMPT  TO  INSTALL,  OPERATE,  OR  SERVICE  THIS  PRODUCT  BEFORE  READING  ALL 

INSTRUCTIONS CAREFULLY. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN 

FIRE

PERSONAL

INJURY

 

AND/OR 

PROPERTY DAMAGE!

 

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE

.

 

The Mitey Midget heater is available in five lengths, ranging 
from 13 inches to 46 inches.  Select from a wide variety of 
wattage’s and voltages, from 500W/120V to 3800W/577V. 
These  models  have a  heavy  duty  aluminum  extrusion  with 
a  bright  aluminum  insert,  an  aluminum  housing,  mounting 
brackets  for  permanent  installation  or  chain  suspension, 
and  an  end-to-end  wireway  for  single  end  wiring  and  easy 
installation.

 

 All  models  are  UL  and  C-UL  (USA  and  Canada)  Listed 
under  file  #E32304,  for  indoor  commercial  and  industrial 
comfort heat applications. 

Not for indoor residential use.

 

DESCRIPTION 

MODEL 

NUMBER 

WIDTH 

LENGTH 

(in.) 

WATTS 

VOLTS 

MM-13A 

 

MM-18A 
MM-18A 

 

MM-24A 
MM-24A 
MM-24A 

 

MM-33A 
MM-33A 

 

MM-46A 
MM-46A 
MM-46A 

 
 
 
 
 
 

3-3/4” 

13 

 

18 
18 

 

24 
24 
24 

 

33 
33 

 

46 
46 
46 

500 

 

1000 
1000 

 

1600 
1600 
1600 

 

2500 
2500 

 

3000 
3800 
3650 

120 

 

208 
240 

 

208 
240 
277 

 

480 
577 

 

480 
577 
480 

 

SPECIFICATIONS 

Read all instructions before using this heater.

 

1. 

Make  certain  that  the  power  source  conforms  to  the 
electrical  requirements  of  the  heater.    Disconnect  power 
before installing or servicing.  If the power disconnect is out 
of  sight,  lock  it  in  the  open  position  and  tag  it  to  prevent 
unexpected  application  of  power.    Failure  to  do  so  could 
result in fatal electric shock. 

 

WARNING:  DO  NOT  DEPEND  UPON  A  THERMOSTAT  OR 
OTHER 

SWITCH 

AS 

THE 

SOLE 

MEANS 

OF 

DISCONNECTING 

POWER 

WHEN 

INSTALLING 

OR 

SERVICING  THE  HEATER.    ALWAYS  DISCONNECT  THE 
POWER  AT  THE  MAIN  CIRCUIT  BREAKER  AS  DESCRIBED 
ABOVE.    FAILURE  TO  DO  SO  COULD  RESULT  IN  FATAL 
ELECTRIC SHOCK. 
 

2. 

This  heater  is  intended  ONLY  for  permanent  installation  in 
accordance  with  the  National  Electric  Code  (NEC),  all 
applicable  local  codes  and  ordinances,  and  all  sections  of 
this  manual.    Any  variance  voids  the  warranty  and  may 
create  unsafe  conditions.    All  wiring  should  be  done  by  a 
qualified electrician, using copper wire only.

 

 

3. 

This  heater  is  intended  for  general  heating  applications 
ONLY.    It  must  NOT  be  used  in  potentially  dangerous 
locations  such  as  flammable,  explosive,  chemical-laden  or 
wet atmospheres. 

IMPORTANT SAFETY INFORMATION 

4. 

Special  attention  must  be  given  to  any  bonding  (grounding) 
information  pertaining  to  this  heater.  To  prevent  the  risk  of 
electrocution,  the  heater  must  be  securely  and  adequately 
bonded.  This  should  be  accomplished  by  connecting  a 
conductor  between  the  service  panel  and  the  green  ground 
screw  provided  in  the  heater.  To  ensure  a  proper  bond,  the 
bonding means must be tested by a qualified electrician.

 

 

5. 

Do not insert fingers or foreign objects into the heater.  Do not 
block or tamper with the heater while it is in operation.  Do not 
touch  heater  while  it  is  in  operation  or  just  after  it  has  been 
turned off, as some parts may be hot enough to cause injury. 

 

6. 

Do not attach ductwork to this heater or attempt to use it as a 
make-up  air  heater.    Such  use  voids  the  warranty  and  may 
create unsafe conditions. 

 

7. 

In cases where property damage may result from malfunction 
of  the  heater,  a  back-up  system  or  a  temperature  alarm 
should be used.

 

 

CAUTION:

  Check branch voltage.  Heaters should be operated at 

voltages  no  higher  than  the  heating  elements  and  the  heater  are 
designed  for.    (Lower  voltages,  however,  pose  no  problem  other 
than a loss of wattage).

 

 
 

ELECTRIC INFRARED HEATER 

MITEY MIDGET 

 

MODEL & PART NO.: 

 

MM-13A    

(04440102) 

MM-18A    

(04427602) 

MM-24A    

(04495402) 

MM-33A    

(04427202) 

MM-46A    

(04420302) 

 

OPERATION 

OPERATION 

OPERATION 

OPERATION –

– INSTALLATION 

 INSTALLATION 

 INSTALLATION 

 INSTALLATION –

– PARTS MANUAL

 PARTS MANUAL

 PARTS MANUAL

 PARTS MANUAL    

If you have questions about the

product you have purchased or would 

like to leave us feedback please 

contact us via our website 

www.fostoriaindustries.com 

or by calling 1-800-495-4525.

Содержание MITEY MIDGET

Страница 1: ...EAKER AS DESCRIBED ABOVE FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC SHOCK 2 This heater is intended ONLY for permanent installation in accordance with the National Electric Code NEC all applicable local codes and ordinances and all sections of this manual Any variance voids the warranty and may create unsafe conditions All wiring should be done by a qualified electrician using copper wire onl...

Страница 2: ...provided from the terminal box through the customer provided conduit and connect the supply wiring inside the customer provided splice box See Figure 2 below 3 Follow local and national electric codes 4 Do not use the heater as a field wiring compartment WIRING 1 2 slack on pigtail Cut off excess Wrap pigtail clockwise around screw Figure 1 Splice box by cust 6 conduit nipple by customer Figure 2 ...

Страница 3: ...Replace element 2 Check connection to outlet Check power 3 Rewind pigtail on socket 1 Add additional heaters 2 Decrease mounting height or distance 1 Replace with smaller heater 2 Increase mounting height or distance A dimension indicates exact spacing between mounting brackets See sketch at right REPLACEMENT PARTS LIST and EXPLODED VIEW TROUBLESHOOTING CHART Model MM 13A MM 18A MM 24A MM 33A MM 4...

Страница 4: ...plicable heating or electrical codes and the manufacturer s installation instructions It further requires that he perform reasonable and necessary maintenance on the unit The company is not liable for abuse or misuse of product as may be finally determined by the company FOSTORIA INDUSTRIES INC 1200 North Main Street Fostoria Ohio 44830 1911 419 435 9201 WARRANTY REF NO 1 2 3 4 5 6 7 8 9 10 11 12 ...

Отзывы: