background image

Model RM-2 Owner’s Manual

6

R

MUTE

MONO

DIGITAL

L

R

MUTE

MONO

DIGITAL

L

R

MUTE

MONO

DIGITAL

L

R

MUTE

MONO

DIGITAL

L

Illuminated

Illuminated

Illuminated

Illuminated

Illuminated

Indication of channel selection

You can see which channel(s) is/are now selected by the [CH SEL] key via the status information
section, as below.

Stereo

Mono (L+R)

Mono (L only)

Mono (R only)

R

MUTE

MONO

DIGITAL

L

R

MUTE

MONO

DIGITAL

L

R

MUTE

MONO

DIGITAL

L

R

MUTE

MONO

DIGITAL

L

Stereo

Mono (L+R)

Mono (L only)

Mono (R only)

Illuminated Illuminated Illuminated Illuminated Illuminated

Illuminated

Illuminated

Illuminated Illuminated

The MUTE indicator shows mute status. When the system mute is active, the MUTE indicator is lit.
When the user mute is active, the MUTE indicator flashes. As the user mute status takes priority to
the system mute status, the MUTE indicator shows the status as follows.

• When the [INPUT] switch is set to "Analog"

• When the [INPUT] switch is set to "Digital"

"System mute" and "user mute"

The RM-2 has two mute functions. One is the "user mute" function which allows you to manually
mute the unit whenever you want, while the other is the "system mute" function which automatically
mute the unit in particular conditions.

R

MUTE

MONO

DIGITAL

L

MUTE LED

Unlit

Lit

Flashing

Flashing

OFF

ON

System mute

OFF

ON

User mute

(1) When you turn on the power.
(2) When you press the [INPUT] switch to switch the input.
(3) When the unit does not lock to the external digital clock while selecting the digital input.

User mute:

The user mute function allows you to mute the unit manually by pressing and hold-

ing down the [CH SEL] key until the [MUTE] indicator lights up (the level meters show the input
levels regardless of the mute condition). You can release muting by pressing the [CH SEL] key
briefly.

System mute:

The RM-2 is automatically muted in any of conditions (1) through (3) below (un-

like the user mute, the level meters do not show the input levels in this case). The system mute
function is activated to prevent the noise from being generated from the speaker units. In the
cases of (1) and (2) below, muting is released after a few seconds. In the case of (3), muting is
released when the unit locks to the external digital signal.

<Note>: 

When you turn on the power, both the user mute and system mute functions are

activated. Therefore, system muting is automatically released after a few seconds but user
muting is not released automatically. So you have to press the [CH SEL] key to release user
muting.

Содержание RM-2

Страница 1: ...Model RM 2 is a rack mountable powered monitor system which allows you to monitor digital or analog audio signals It incorporates a 10 W x 2 power amplifier and outputs signals from the inter nal speakers or from the headphones output jack You can check the input level via the 26 dot LED meters Read this owner s manual thoroughly before using We hope you will use the RM 2 for a long time Table of ...

Страница 2: ...flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servici...

Страница 3: ...oes not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or s...

Страница 4: ...receive a correct digital signal or does not work cor rectly the DIGITAL indicator flashes DIGITAL You can monitor the analog signals re ceived via the ANALOG INPUT connec tors When the INPUT switch is set to ANALOG Notes When switching the input signal be tween analog and digital the system mute function works and unit is automatically muted for a while the MUTE indicator lights This prevents the...

Страница 5: ... 4 combi jacks You can connect an XLR 3 12C connector or 1 4 plug to each of these combi jack type ANALOG INPUT connectors you cannot insert both together Each connector accepts a 4 dBu analog signal via XLR connection or a 10 dBV analog signal via 1 4 connection 1 2 3 1 2 3 5 CH SEL channel select key This key switches the channel s to be monitored Each press of the key switches the channel s in ...

Страница 6: ... mute function which automatically mute the unit in particular conditions R MUTE MONO DIGITAL L MUTE LED Unlit Lit Flashing Flashing OFF ON System mute OFF ON User mute 1 When you turn on the power 2 When you press the INPUT switch to switch the input 3 When the unit does not lock to the external digital clock while selecting the digital input User mute The user mute function allows you to mute th...

Страница 7: ...re Rated output power 20 mW 20 mW 32 ohms 1 kHz Level meters 26 dot LED meter x 2 When digital input is selected Peak metering 0 dB 0dBFS When analog input is selected VU metering 0dB 4 dBu 10 dBV General External dimensions 430 W x 44 H x 260 D mm Weight Approximately 3 5 kg Power requirement 120VAC 60Hz for US and CANADA version 230VAC 240VAC 50 60Hz for Europe version Power consumption 10 W Sup...

Страница 8: ... PRINTED IN JAPAN OCT 2005 FX 436827 FOSTEX CO 3 2 35 Musashino Akishima shi Tokyo Japan 196 0021 FOSTEX AMERICA 13701 Cimarron Avenue Gardena CA 90249 U S A ...

Отзывы: