G3 Counters - Service Manual
Controller Menu’s
The controller contains 2 menu levels, user level and service level.
User Level Menu
To access user level settings, press button 3 and then press button 1. The display will show ‘SP’. Use buttons 2 and 4 to display the parameter
required. Press button 3 to display the current value. If it is required to amend the value use buttons 2 and 4 followed by button 3 to save the new
value.
User Level Parameters
M
nemonic
Description
SP
Appliance Set Point
Loc
Keypad Lock
tA
Actual air probe value
tE
Actual evaporator probe value (Not enabled on all models)
tLo
Minimum air temperature during previous 24 hours
tHi
Maximum air temperature during previous 24 hours
dEF
Time until next scheduled defrost. Displayed in tenths of hours. For example 05.4 = 5 hours 40 minutes
tdy
Display resolution
Service Function