Defrost

LR150 & LR410 models have static freezer shelves and require manual defrosts. The entire stored product 

should be removed and placed in a separate freezer. Switch off the mains electrical supply and leave the cabinet 

door open while placing a bowl inside to catch the water as it defrosts. Once fully defrosted dry the interior of 

the cabinet and switch on the mains supply.

Do not replace frozen food into the cabinet until it reaches its normal operating temperature.

All other models

 are fitted with a fully automatic defrost system to ensure that the evaporator coil or cooling 

plate remains free from ice in normal use. ‘Melt water’ is automatically evaporated using the heat from the 

refrigeration system.

Cleaning and Maintenance

Important: Before cleaning, the unit should be put into standby and then the power supply should be turned 

off at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has been completed 

and the unit is dry should the cabinet be turned back on at the mains. 

Suitable P.P.E (Personnel Protective Equipment) should be worn at all times.

Regular Maintenance:

>

 

 

As and when required remove all product and shelving (beware of cold and or sharp components) from  

  

the unit. Clean exterior and interior surfaces with mild liquid detergent, following the directions on the   

  

pack at all times. Rinse surfaces with a damp cloth containing clean water. Never use wire wool, scouring    

  

pads/powders or high alkaline cleaning agents i.e bleaches, acids and chlorines as these may cause  

 damage.

>

 

 

Condenser Cleaning: 

 

This should take place on a regular basis or as and when required (4 to 6 weeks) by a competent/trained  

 personnel. 

  

Use a soft brush or vacuum cleaner to remove dirt/dust. If there are any stubborn grease deposits left  

 

on or through the condenser call your supplier to carry out a full service (this is normally chargeable).  

 

Failure to maintain the condenser may invalidate the warranty of the condensing unit and cause    

 

premature failure of the motor/compressor. Do not use a wire brush to clean the condenser. Hoover or  

 

brush the air filter (where fitted).

 

All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a warm  

 

damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry.

>

 

 

Removable shelves and their supports can be removed for cleaning. The shelves are dishwasher safe;  

 

however the vertical supports should be cleaned with warm soapy water then rinsed and dried.

Содержание ECO HR410

Страница 1: ... II Suppliers of Commercial Refrigeration Foster Refrigerator King s Lynn Foster Refrigerator Oldmedow Road King s Lynn Norfolk PE30 4JU United Kingdom A division of ITW Ltd Email support foster gamko com www fosterrefrigerator co uk Call 44 0 1553 691 122 ISO 9001 ISO 14001 English Original Operation Instructions 00 556435 UK November 2019 Issue 6 5 ...

Страница 2: ...st be of the value stated on the serial label for the cabinet General Safety Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Keep all ventilation openings in the appliance or in the structure of a built in unit clear of any obstructions Do not use electrical appliances inside the storage compartment The appliance is air tight when the door is cl...

Страница 3: ...erformance Make sure that a minimum clearance of 50mm above and around the cabinet is available for ventilation and effective operation Connect the unit to a suitable mains power outlet and turn the supply on Please do not plug or unplug the unit with wet hands The cabinet will start automatically displaying the actual internal temperature of the unit area where product is stored As the operating ...

Страница 4: ...e fitted The on off switch is located on the front of the light fitting Shelves Supports Drawers Shelves H models are supplied with slotted removable shelf supports The only L models that have fixed shelves that are part of the freezer system and cannot be removed are the LR150 A XR415L all other L models have removable shelves Refrigerated Drawers can be removed by pulling out to their full exten...

Страница 5: ...English Drawer Removal This guide applies only to models that have drawers fitted ...

Страница 6: ...when required remove all product and shelving beware of cold and or sharp components from the unit Clean exterior and interior surfaces with mild liquid detergent following the directions on the pack at all times Rinse surfaces with a damp cloth containing clean water Never use wire wool scouring pads powders or high alkaline cleaning agents i e bleaches acids and chlorines as these may cause dama...

Страница 7: ... your supplier please make sure that a The plug has not come out of the socket and the mains power supply is on i e is the controller illuminated b Check to see if the unit is in standby c The fuse for the cabinet is intact d The cabinet is positioned correctly cold or warm air sources are not affecting the performance e The condenser is not blocked or dirty f The products are placed in the unit c...

Страница 8: ...ual is also available for download in the following languages Français FR Nederlands NL Deutsch D Español ES Česky CZ Pусский RU Polski PO To download please visit www foster spares com and select the appropriate model of refrigerator freezer ...

Страница 9: ...English Page Left Blank Intentionally ...

Страница 10: ...English Page Left Blank Intentionally ...

Страница 11: ...English Page Left Blank Intentionally ...

Страница 12: ...English UK Head Office Foster Refrigerator Oldmedow Road Kings Lynn Norfolk PE30 4JU a Division of ITW UK Ltd Tel 44 0 1553 691 122 Email support foster gamko com Website www fosterrefrigerator co uk ...

Отзывы: