![fos4X Blackbird OECD MDE1195 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/fos4x/blackbird-oecd-mde1195/blackbird-oecd-mde1195_instructions-for-use-manual_2322767022.webp)
3. Product Description
Figure 8: LEDs on the PWR connector
1
Status-LED
2
Power-LED
Table 16: POWER-LED on the PWR connector
POWER-LED
Meaning
On
Power supply OK
Off
No power supply
STATUS-LED
Table 17: STATUS-LED on the PWR connector
STATUS-LED
Green
Yellow
Red
On
System healthy Measurement
warning
Measurement
error
Slow flashing
Sytem auto
adjust
-
System error
Fast flashing
-
Identify
System not
adjusted
TIP
The STATUS-LED flashes quickly every 4 s when in the state
On
.
Table 18: STATUS-LED and device state
Device state
Description
System healthy
Normal operation
22 / 76
MDE1195_4-10_1.3.x_5.0_Blackbird
OECD_(9CH, PRN)-en-us
© fos4X 2020