4. Packaging and Transport

4.4 Packing

Packing the measuring device in the original packaging:

1.

Open the box.

2.

Put the lower foam part in the box.

3.

Put the measuring device into the cut-out in the foam part. Make sure the
measuring device is in the correct position.

4.

Put the upper foam part in the box. Make sure the cut-outs are in the correct
position.

5.

Close the box.

P

Blackbird OECD ready for transport or shipping.

Alternative: Packing the measuring device in a different packaging:

1.

Choose a box so that the measuring device with padding material fits into the
box.

2.

Open the box.

3.

Pack the measuring device in the box with padding material. Make sure that the
measuring device is protected against shocks from all sides.

4.

Close the box.

P

Blackbird OECD ready for transport or shipping.

4.5 Transport

Transporting the Blackbird OECD:

u

Handle the Blackbird OECD with care during transport.

u

Observe the transport conditions. See 

Environmental Conditions, page 15

.

u

Pack the Blackbird OECD in a transport packaging. See 

Packing, page 26

.

26 / 48

MDE1185_4-10_1.3.x_5.0_Blackbird

OECD_(6CH, ETH)-en-us

© fos4X 2020

Содержание Blackbird OECD MDE1185

Страница 1: ...pe Measuring device Product Version 1 3 x Document Version 5 0 Issue Date 2020 02 07 Language en us INSTRUCTIONS FOR USE Blackbird OECD 6CH ETH MDE1185 Product Type Measuring device Product Version 1...

Страница 2: ...Violations will result in the liability for damages All rights reserved in the event of patent utility model or design registration All rights reserved fos4X is a trademark of fos4X GmbH Brand names...

Страница 3: ...tion of Personnel 9 2 4 Intended Use 10 2 5 Residual Risks 10 2 5 1 Explosion Protection 10 2 5 2 Working Environment Wind Turbine 10 3 Product Description 11 3 1 Functional Description 11 3 1 1 Overv...

Страница 4: ...ge 27 5 Installation 28 5 1 Important Safety Notes for Installation 28 5 2 Attaching the Measuring Device in the Control Cabinet 28 5 3 Connecting the Interfaces 28 5 4 Connecting the Power Supply 29...

Страница 5: ...9 2 2 Replacing the PWR Connector 39 9 2 3 Firmware Update 40 9 3 fos4X Support 42 9 4 Spare Parts and Accessories 43 10 Taking out of Service and Disposal 44 10 1 Taking out of Service 44 10 2 Disass...

Страница 6: ...afety chapter applies to the entire use of the product See Safety page 9 Safety notes at the beginning of a section apply to the entire section Safety notes before a step apply to the entire following...

Страница 7: ...f an instruction List Point 1 Point 2 Enumeration with title Identification of Information page 6 Cross reference Bold Text Highlighting of particularly important information Software text Text parame...

Страница 8: ...Max Maximum MTBF Mean Time Between Failures OECD Opto Electronic Converter Device PC Personal Computer SMF Single Mode Fiber UDP User Datagram Protocol 8 48 MDE1185_4 10_1 3 x_5 0_Blackbird OECD_ 6CH...

Страница 9: ...rained personnel Personnel trained in the operation and safe use of the product Qualified personnel Personnel who based on their specialist training knowledge and experience and knowledge of the relev...

Страница 10: ...Residual Risks 2 5 1 Explosion Protection The product is not suitable for use in potentially explosive environments 2 5 2 Working Environment Wind Turbine The use of the product in wind turbines requi...

Страница 11: ...ew TIP Number of channels depends on the variant Figure 1 Overview 1 Mounting plate 2 E 2000 connectors 3 PWR connector 4 Data interfaces The Blackbird OECD consists of the following components Mounti...

Страница 12: ...are connected via fiber optical cables to the E 2000 APC connectors of the Blackbird OECD The Blackbird OECD evaluates the signals of the sensors and provides the wavelengths of the individual sensor...

Страница 13: ...n Time Protocol 300 s 1 Standard deviation at a sampling frequency of 5 Hz 2 At wavelength 1552 nm and signal level 60 3 Time between power up and operation within specification Requirements for senso...

Страница 14: ...or RJ45 Transfer rate 10 100 Mbps Max Output rate 1000 Hz Protocol IPv6 PTP protocol IEEE 1588 PTPv2 3 2 3 Optical Data Table 7 Optical Data Property Value Unit Connector type E 2000 APC Fiber type SM...

Страница 15: ...ction class IP20 Maximum operating altitude 3000 m Permitted temperature Transport and storage 40 85 C Permitted relative humidity Non condensing Transport and storage 5 95 Permitted temperature Opera...

Страница 16: ...3M6 IEC 60068 2 2 Class 3M6 Electromagnetic Compatibility IEC 61326 1 EN 55032 MTBF Table 11 MTBF Property Value Unit MTBF 100000 h 3 2 7 Mechanical Data Table 12 Mechanical Data Property Value Unit L...

Страница 17: ...3 Product Description 3 2 8 Dimensions TIP Number of channels depends on the variant Figure 4 Dimensions front view fos4X 2020 MDE1185_4 10_1 3 x_5 0_Blackbird OECD_ 6CH ETH en us 17 48...

Страница 18: ...3 Product Description Figure 5 Dimensions top view 18 48 MDE1185_4 10_1 3 x_5 0_Blackbird OECD_ 6CH ETH en us fos4X 2020...

Страница 19: ...e serial number CE marking RoHS marking Indication of the laser class of the product Class 1 Laser Product Power supply 12 24V Power consumption max 15W Optional Device designation KF123 Optional Cust...

Страница 20: ...ion On LED is continuously on Slow flashing 1 s Fast flashing 1 s Single flash 1 s Double flash 1 s Triple flash 1 s Quadruple flash 1 s 3 4 1 2 LEDs on the PWR connector There are 2 LEDs on the PWR c...

Страница 21: ...n the PWR connector STATUS LED Green Yellow Red On System healthy Measurement warning Measurement error Slow flashing Sytem auto adjust System error Fast flashing Identify System not adjusted TIP The...

Страница 22: ...Identify Status is activated by a network command The blink pattern can be used to identify the Blackbird OECD System error Error in the power supply Error in the light source General system error Sy...

Страница 23: ...ctions Signal Warning There are one or more warnings See Tab 19 Signal Quality page 23 Measurements are possible The measurements may be inaccurate due to boundary effects and environmental conditions...

Страница 24: ...messages Communication takes place via IPv6 link local addresses The fos4X multicast address ff02 13c is used for device recognition For communication via the Ethernet interface fos4X recommends the u...

Страница 25: ...ackbird OECD is packed in a box with foam inserts One box contains up to 5Blackbird OECD The box has the dimensions 645 x 492 x 216 mm length x width x heigth 4 3 Unpacking Unpacking the the measuring...

Страница 26: ...device in a different packaging 1 Choose a box so that the measuring device with padding material fits into the box 2 Open the box 3 Pack the measuring device in the box with padding material Make su...

Страница 27: ...Store the Blackbird OECD in a dry and clean place u Store the Blackbird OECD in a transport packaging See Packing page 26 u Observe the environmental conditions See Environmental Conditions page 15 fo...

Страница 28: ...the Control Cabinet Conditions Control cabinet with sufficient space for installation See Dimensions page 17 Control cabinet with permissible environmental conditions See Environmental Conditions pag...

Страница 29: ...the MC 1 5 2 GF 3 81 connector to the PWR connector 4 Switch on the power supply 5 5 Connecting a Sensor NOTICE Poor signal quality due to dust and dirt on the sockets and connectors Optical connectio...

Страница 30: ...om the socket 4 2 Clean the sockets 4 with an optical connector cleaner See manual of the optical connector cleaner 3 Carefully open the protective cover 3 on the connector 2 4 Clean the connector 2 w...

Страница 31: ...ructions See Safety page 9 6 1 Commissioning the Ethernet Interface For communication via the Ethernet interface fos4X recommends the use of the fos4X C API See fos4X C API documentation fos4X 2020 MD...

Страница 32: ...7 1 Monitoring Operation In normal operation of the Blackbird OECD no operating actions are necessary u Monitor operation via an interface See Software page 23 In case of errors see Troubleshooting pa...

Страница 33: ...tions do not help to fix the problem u Contact fos4X Support See fos4X Support page 42 Table 21 Troubleshooting PWR LEDs Problem Possible cause Solution POWER LED on the PWR connector is not on Blackb...

Страница 34: ...ns properly Configuration error u Do a firmware update See Firmware Update page 40 STATUS LED on PWR connector does not light green See LEDs on the PWR connector page 20 System error 1 Check the power...

Страница 35: ...range See Measurement and Sensors page 12 u Make sure that only permitted sensors are connected See Measurement and Sensors page 12 Temperature Too Low or Temperature Too High u Make sure to operate...

Страница 36: ...supply off and on Calibration Missing u Contact fos4X Support See fos4X Support page 42 No Signal u Make sure that a sensor is connected u Clean the optical connectors See Cleaning E 2000 APC Connecti...

Страница 37: ...he Ethernet cable for damage u Check that the Ethernet cable is plugged in Error in the Ethernet network u Check the Ethernet network and configuration No Ethernet connection Blackbird OECD defective...

Страница 38: ...nce 9 2 1 Cleaning E 2000 APC Connections Figure 12 E 2000 APC connector and socket 1 Locking mechanism 2 Connector 3 Protective cover 4 Socket 5 Dust cap Table 24 Material and equipment Name Type Qua...

Страница 39: ...00 APC connection is cleaned 10 Repeat the procedure for all connections 9 2 2 Replacing the PWR Connector Table 25 Material and equipment Name Type Quantity GTIN Power supply connector MC 1 5 2 GF 3...

Страница 40: ...ware fos4X Firmware Flasher f3 exe 1 Conditions Firmware archive for the Blackbird OECD available IPv6 protocol enabled on the PC Doing a firmware update via fos4X Firmware Flasher 1 Stop the normal o...

Страница 41: ...correct network adapter is selected c Make sure that the IPv6 protocol is enabled on the PC d Make sure that the PC has a valid IPv6 link local address e Click on in Network Interface 7 Click on in F...

Страница 42: ...een check mark Click on FLASH BOOTLOADER FIRMWARE The status of the update is displayed in a new window 13 Wait until the firmware update is complete 14 Disconnect the PC from the Blackbird OECD 15 If...

Страница 43: ...Type Manufacturer GTIN Power supply connector MC 1 5 2 GF 3 81 Phoenix Contact 4017918050313 Accessories Table 28 Accessories Name Type Manufacturer GTIN Optical connector cleaner OCC A Ultra Fujikura...

Страница 44: ...se the locking mechanism 1 of the connector 2 b Remove the connector 2 from the socket 4 c Attach a dust cap 5 on the socket 4 d Repeat the procedure for all sensors 3 Remove the power cable from the...

Страница 45: ...sposal of the product Improper disposal of the product may cause damage to the environment u Observe applicable environmental regulations The Blackbird OECD is an electrical appliance and must not be...

Страница 46: ...content 19 Fig 7 LEDs on the PWR connector 21 Fig 8 LED on the Ethernet connector 22 Fig 9 ETH connector 28 Fig 10 PWR connector 29 Fig 11 E 2000 APC connector and socket 30 Fig 12 E 2000 APC connect...

Страница 47: ...16 Tab 13 Mounting 16 Tab 14 LED Flashing Patterns 20 Tab 15 POWER LED on the PWR connector 21 Tab 16 STATUS LED on the PWR connector 21 Tab 17 STATUS LED and device state 21 Tab 18 LED on the Ethern...

Страница 48: ......

Отзывы: