3. Product Description
0x2005 Offset
Description
Object 0x2005 contains the offset for all channels.
Each sub-object of 0x2005 corresponds to one channel of the device. Example:
0x2005sub1 contains the value for the first channel.
Object 0x2005 is read-only.
Sub-Objects
All sub-objects are 32 bit unsigned integers.
The sub-objects contain the 20 bit fix point representation of the wavelength. To
calculate the wavelength, the raw value must be divided by 1048576.
Sub-Objects for channels that are not present contain the value 0.