background image

  

  

  

11

 

 

 

 

 

Following are a  few common problems that may occur during operation.Here are some suggestions for 

easy troubleshooting: 

 

1. 

The unit does not work, no light and the fan does not work 

 

 

check the connection of power and main fuse. 

 

Measure the mains voltage on the main connector. 

 

Check the power on Led. 

 

2. 

Not responding to DMX controller 

 

 

DMX LED should be on. If not ,check DMX connectors, cables to see if link properly. 

 

If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. 

 

If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit 

or the previous one. 

 

Try to use another DMX controller. 

 

Check if the DMX cables run near or run alongside to high voltage cables that may cause damage 

or interference to DMX interface circuit. 

 

3. 

Some units don’t respond to the easy controller 

 

You may have a break in the DMX cabling. Check the LED for the response of the master/slave 

mode signal. 

 

Wrong DMX address in the unit. Set the proper address. 

 

4. 

One of the channels is not working well 

 

 

The stepper motor might be damaged, or the cable connected to the PCB is broken. 

 

The motor’s drive IC on the PCB might be out of condition 

5. 

Fixture Cleaning 

 

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 

damp,  smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. 

Содержание Pico Pro

Страница 1: ...FOS Pico Pro PRODUCT SPECIFICATIONS...

Страница 2: ...t be maintained between the equipment and a combustible surface The product must always be operated in a well ventilated area DO NOT stare directly into the light source Always disconnect the power be...

Страница 3: ...OFED POWER AND SIGNAL LINK IP67 shielded against dust and protected for accidental briefly submerge PROTECTION AGAINST ACCIDENTIAL SUBMERGING ON TEMPORARY FLOODED AREA TEMPORARY USE Event equipment is...

Страница 4: ...ing a standard mounting clamp Please note that when hanging the unit a safety cable should also be used UPRIGHT The fixture can be mounted in an upright or sitting position using the supporting bracke...

Страница 5: ...Menu Operation DMX When DMX Signal in the LED will be flash ERR When the Light error the LED will be flash Mode ESC ENTER Left button Right button Up button Down button...

Страница 6: ......

Страница 7: ...movement 0 225 max to min speed 226 235 Blackout by movement 236 255 No function 6 4 Pan Motor continuous rotation 0 127 no function 128 189 Forwards Pan rotation from fast to slow 190 193 No rotatio...

Страница 8: ...8 10 8 Blue LED 0 255 Blue 0 Black 255 100 Blue 11 9 White LED 0 255 White 0 Black 255 100 White...

Страница 9: ...REEN 72 103 From GREEN to CYAN 104 135 From CYAN to BLUE 136 167 from BLUE to MAGENTA 168 199 from MAGENTA to RED 200 231 from RED to WHITE 232 255 Cross fading colours from slow to fast 15 13 Color P...

Страница 10: ...o8 General Information Replacing a fuse Always disconnect the fixture from main power before replacing a fuse Use only the appropriate fuse with the same type and rating A fuse with different rating c...

Страница 11: ...oller Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 3 Some units don t respond to the easy controller You may...

Страница 12: ...12 Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully...

Отзывы: