L005614 FOS TV FRESNEL WW USER MANUAL L005614 FOS TV FRESNEL WW USER MANUAL
When suspending the fixture above ground level, verify that the structure can hold at least
10 times the weight of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and use an
approved means of secondary attachment such as a safety cable.
Ⅴ
CONTROL PANNEL
B
UTTON
MENU
UP
DOWN
ENTER
Call the main menu, or escape the current menu, (i.e. return to the
upper menu and give up the selected item or parameter).
Browse the menu item forward or increase the parameter.
Browse the menu item backward or decrease the parameter.
Confirm the selected item or parameter, (i.e. enter into the next menu,
or escape the current menu and save the selected item or parameter).
I
NDICATOR
There are 4 dots at the bottom of the digital tube, from left to right as:
1. DMX signal LED indicator;
2. Memory writing indicator, (Press
ENTER
after amending the DATA, This Dot will be light
up, it means the Data is saving);
3. Power indicator;
Every person involved with the installation, operation and maintenance of this device has to
be qualified and follow the instructions of this manual. Manufacturer will not with
responsibility for those operations which are not according to this Instruction.
Verify that the voltage matches the rated voltage.
When the voltage is 110V, Do not connect more than 10 lightings in total to AC mains
power in one interconnected daisy chain
When the voltage is 220V, Do not connect more than 20 lightings in total to AC mains
power in one interconnected daisy chain
Before using the fixture, check that all power distribution equipment and cables are in
perfect condition and rated for the current requirements of all connected devices.
Always ground (earth) the fixture electrically.
Avoiding hit the Light when you are move or install the light.
The minimum distance between light-output and the illuminated surface must be more
than 0.5 meters. Keep all combustible materials (for example fabric, wood, paper) at least
0.2 meters away from the fixture.
Do not expose the fixture to rain or moisture.
Avoid looking directly into the light source (especially those who suffer from epileptic fits)
Maximum ambient temperature (Ta) is 40°C. Do not operate fixture at temperatures higher
than this.
The Maximum surface temperature is 50°C
When suspending the fixture above ground level, verify that the structure can hold at least
10 times the weight of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and use an
approved means of secondary attachment such as a safety cable.
Ⅳ
POWER CONNECTION
I
NSTALLING A
N
ENUTRIK
C
ONNECTOR ON A
P
OWER
C
ABLE
03