16
ADVANCED Three phase charger 208-240-480V in I2c cabinet / Chargeur type ADVANCED Triphasé 208-240-480V dans le caisson I2c
12 mar 15
150_23_rev00
Advanced
Three phase charger
WH
BN
BK
t°
OFF
10
9
7
8
B
N
B
N
B
R
O
W
N
B
R
O
W
N
5
4
2
1
3
R
E
D
B
N
R
D
V
T
B
K
B
U
B
U
B
L
U
E
V
IO
L
E
T
B
L
A
C
K
G
R
E
Y
B
R
O
W
N
6
TERMINAL AT12
F1
Fwd
M
Rew
AT13
Faston
GND
KA
RD
BATTERY FUSE
GY
BATTERY
FUSE
RD
BK
BN
L3
BU
BN
BN
GY
L1
L2
BK
VT
DIODIES BRIDGE
POWER
TRANSFORMER
GY
D-Delta
Y-Star
2
1
3
TM1
7
8
+B
GND
T°
R-TA
11V-50Hz
10A/250V
4
1
6
A1
A2
5x20 T500mA
FU3
5
TA
3
4
2
1
10
9
+B
-B
FU1
(+)
(-)
A.C.
A.C.
A.C.
VD1
T3
T2
T1
L3
L2
L1
KM1
2
3
1
9
7
8
V1
W1
U2
V2
U1
W2
L1
L2
L3
J
7 - 8 - 9
K
L
KM1
23
CARD
G2
AT13
CARD
G1
AT12
B
C
D
1 - 2 - 3
Y
D
220
208
200
250
240
230
500
480
460
K
J
L
K
J
L
K
J
L
C
B D
C
B D
C
B D
BK
L3
L1
L2
Advanced
GND
F
U
5
5x20 F500mA
(B) 480V - 60Hz model 3NAT4 - 5NAT4 (default)
AC Main Three phase
Charger can ber adaptable to ...
Permanently Connected
(C) 240V - 60Hz
(D) 208V - 60Hz
Cabinet I2c
Serie 3N - no Display AT13 (G2)
Serie 5N - with Display AT13 (G2)
TM2 40VA
AUXILIARY
TRANSFORMER
0V
0V
11V
24V
F
U
2
5x20 F2A
F
U
4
6,3x32 T500mA
WH VT BU
208V
240V
480V
B
A
B
A
B
A
B
A
B
A
B
A
B
A
-
C
D
1-2-3
B
-
-
C
D
1-2-3
B
-
-
B
1-2-3
D
C
-
1-2-3
C
B
-
1-2-3
C
B
-
-
B
D
D
D
D
D
208V
AUX. CIRCUIT
200V
SETTING
-
L
-
K
J
7-8-9
7-8-9
K
L
-
J
-
-
SETTING
208V
AUX. CIRCUIT
208V
208V
AUX. CIRCUIT
220V
SETTING
-
K
L
7-8-9
480V
AUX. CIRCUIT
460V
Y
SETTING
1-2-3
B
-
L
-
K
J
7-8-9
7-8-9
K
L
-
J
-
B
1-2-3
SETTING
Y
480V
AUX. CIRCUIT
480V
480V
AUX. CIRCUIT
500V
Y
SETTING
1-2-3
B
-
K
L
7-8-9
7-8-9
L
K
-
-
D
SETTING
250V
AUX. CIRCUIT
240V
240V
AUX. CIRCUIT
240V
SETTING
D
-
-
J
-
L
K
7-8-9
7-8-9
J
K
-
L
-
-
D
C
1-2-3
SETTING
230V
AUX. CIRCUIT
240V
D
3
9
2
8
L
K
J
D
B C
L
K
J
D
B C
C
B
D J K L
7
1
-
J
D
-
-
C
C
-
-
D
C
-
-
D
J
-
J
-
Components Plate
A
B
A
B
Keep the following information as guidelines. Read carefully the instructions for details
WARNING: No Voltage into the charger when you move the wires. Disconnect Mains and Battery plugs
1) First check the AC main Voltage on the Main Terminals and then switch off
2) Check or Move the "Auxiliary circuit" (A) to the right range (208V - 240V or 480V)
3) Check or Move the "Changer" (B) in the right position (208V and 240 DELTA while 480V STAR ).
4) Check or Move the wires 1-2-3 in the right position (B=480V C=240V D=208V).
5) Check or Move the wires 7-8-9 to the closer position in the selected range. (see table)
AC Main
Cable
Battery
Cables
Secondary
GND
GND
MAIN
STAR - Y
U1 V1 W1
V2
U2
W2
B
A
208V
240V
480V
L1
L2 L3
ADVANCED models
3NAT4 and 5NAT4 480V-60Hz in Cabinet I2c
Mains 491 - 510V
Mains 246 - 253V
Mains 216 - 225V
Mains 205 - 215V
Mains 236 - 245V
Mains 471 - 490V
Mains 450 - 470V
Mains 226 - 235V
Mains 200 - 204V
9
L
K
J
D
C
B
130
125
120
115
435 4 34
terminal can change in according with power transformer
115 120 125 130
B C D J K L
17 apr 15
155_09 rev00
ADVANCED 208-240-480V-60Hz
Three phase chargers in I2 Cabinet