For further assistance, please contact us at [email protected]
UPS mode
LCD
Description
When the UPS is overloaded, the unit
beeps every 0.5 second to warn about
such condition
Overload in battery
mode
The icon is displayed on the
screen
Fault condition
LCD
Solution
Disconnect short-circuited
loads and restart the UPS
The output is short circuited
Remove all connected loads
and restart the UPS
Overload fault
Call for technical assistance
immediately
Overcharge
Please replace the battery
Defective or severely
discharged battery
Call for technical assistance
immediately
High output voltage
1. Turn off and wait for the unit
to cool
2. Or remove excessive loads
and wait for the unit to cool
Over-temperature
The icon is displayed when
battery level is low
When the UPS is in battery mode and
battery voltage begins to dwindle, the unit
will beep once every 10 seconds. Also when
the LCD is touched, the information will be
displayed in the following order:
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Battery mode
8. Technical specifications
* 2 years on batteries
**Calculated with a single PC plus monitor
7. Troubleshooting guide
If the UPS system does not operate correctly, use the table below to troubleshoot the problem.
MPN
General
Input
Output
Battery
Voltage regulation
Line/Battery transfer
Alarms/Indicators
Protection
Special features
Capacity
Physical appearance
Additional information
Nominal voltage
Voltage range
Frequency
AC plug style
Nominal voltage
Frequency
Frequency stability
Waveform
Total outlets
Full battery with surge
protection outlets
Surge protection only outlets
Network protection
Phone/modem/fax protection
USB Management
High cutoff
Boost
Buck
Low cutoff
Battery type and quantity
Weight
Warranty
Visual indicators
Joules
Dimensions
Audible tone
Housing
Color
Recharge time
Backup time
660J
SL-1012UL-A
1000VA/600W
12V / 7Ah (2)
50 min**
17.6lb
5
1
12.6x5.1x7.2in
6 (Argentina Type I)
510J
SL-802UL-A
800VA/480W
12V /9Ah (1)
32 min**
11lb
3
1
11.8x3.9x 5.6in
4 (Argentina Type I)
Typical transfer time
Low-line transfer to battery
High-line transfer to battery
Cold “start option”
Auto charge
Environment
Operating temperature
Storage humidity
Relative humidity
Audible noise
Frequency regulation
Automatic frequency
regulation
220V
162-268VAC
45-65Hz (autosensing)
Argentina Type I
220V +/- 10%
50/60Hz
+/- 1Hz battery mode
Modified sine wave
Included with ForzaTracker software
3 years *
4 hours to 90% after complete discharge
Easy to read LCD with blue backlight that displays battery status, input
voltage, output voltage, load level, and UPS status
ABS fire retardant plastic
Black
Battery mode: Sounds every 10 seconds
Low battery: Sounds every second
Overload: Sounds every 0.5 second
Fault: Sounds continuously
RJ-45
RJ-11
268V +/- 5%
162-204V +/- 5%
236-268V +/- 5%
162V +/- 5%
2-4ms
/- 5%
/- 5%
Included
Included
32-104°F
-4-113°F
0-90% non-condensing
<40dB at one meter
Included