The FTS05x module has been tested for use in European countries. The following testing has been completed:    
Test standard EN 300 220 ; (2012-05)                                 Test standards ETSI EN 301 489-1 ; (2011-09) 
A helpful document that can be used as a starting point in understanding the use of short range devices (SRD) in Europe is the European Radio 
Communications  Committee  (ERC)  Recommendation  70-03  E,  downloadable  from  the  European  Radio  Communications  Office  (ERO) 
http://www.ero.dk.  

The end user is responsible for ensuring compliance with harmonized frequencies and labeling requirements for each 

country the end device is marketed and sold.  

A Declaration of Conformity must be issued for each of these standards and kept on file as 

described in Annex II of the R&TTE Directive. 

 

The  Waste  Electrical  and  Electronic  Equipment  (WEEE)  directive  (2002AA/96/EC)  was 
approved by the European Parliament and the Council of the European Union in 2003. This 
symbol indicates that this product contains electrical and electronic equipment that may 
include batteries, printed circuit boards, liquid crystal displays or other components that 
may  be  subject  to  local  disposal  regulations  at  your  location.  Please  understand  these 
regulations and dispose of this product in a responsible manner. 

 

Limited Warranty 

THE  PRODUCT  IS  PROVIDED  WITH  ONE  YEAR  LIMITED  MANUFACTURER  WARRANTY.      FORTREZZ,  LLC 
warrants its products to be free from defects in material and workmanship under normal use for one year, 
and  is  not  responsible  for  consequential  damages  or  installation  costs  of  any  nature.  FORTREZZ,  LLC. 
expressly  disclaims  all  implied  warranties,  including  but  not  limited  to  the  implied  warranties  of 
merchantability and fitness for a particular purpose.   FORTREZZ, LLC. does not warrant, guarantee, or make 
any  representations  regarding  the  use  or  the  results  of  the  use  of  the  products  or  any  accompanying 
materials in terms of their correctness, accuracy, reliability or otherwise. In no event shall FORTREZZ, LLC. be 
liable to Purchaser hereunder or in respect of any products ordered or delivered to Purchaser, whether in 
contract,  tort  including  negligence  or  otherwise  for  a  loss  of  profits  or  loss  of  use  or  for  any  incidental, 
consequential,  special  or  indirect  damages  howsoever  caused  whether  or  not  FORTREZZ,  LLC.  has  been 
advised of the possibility of such loss or damage. FORTREZZ, LLC's maximum liability to Purchaser under 
these conditions shall in no event exceed the amount paid by Purchaser for the products that are the subject 
of the claim and in respect of all claims for products ordered from FORTREZZ, LLC. to which these conditions 
apply to the amount paid by Purchaser for the products which are the subject of the claims. If you are not 
comfortable with your limited warranty, or not completely satisfied with the MIMO, or the FTS05x does not 
perform as expected we encourage you to return the FTS05x to your DISTRIBUTOR for an exchange or for a 
full refund within 30 days of purchase.  Or, you can return the FTS05x to FORTREZZ, LLC with an RGA number.

 

All products to be returned to FORTREZZ, LLC. must have a valid Returned Goods Authorization (RGA). 

Send the returned unit to: 

FortrezZ, LLC Warranty Replacement, 5440 Highway 55, Lake Wylie SC 29710,

 postage prepaid with a payment of US$ 

9.95 to cover the cost of return shipping, postage and handling. You must use the original packaging and include a proof of purchase (photocopy 
of receipt) along with the RGA # and the returned product.

Содержание FTS05

Страница 1: ...ts your needs and specifications Using the FTS05x in a Z WaveTM Network Program Switch for Network Add Remove The switch is used for adding into or removing from a Z WaveTM network Refer to your controller s User Manual for specific details A Security Enabled controller must be used to fully utilize the FTS05x Add Inclusion into a network 1 Set up the Add Inclusion mode at the controller 2 Briefly...

Страница 2: ...ciation Basic Set messages and Alarm alert messages may be configured and sent Drying or submerging FTS05P only the sensor contacts will clear the Water Alarm If an over under temperature Alarm occurred and the temperature alarm conditions are no longer present an alarm clear message is also sent Also depending on your Z WaveTM controller it is possible to receive a remote alert For example with s...

Страница 3: ...y using the longest acceptable interval between temperature updates The temperature report was not included in the Lifeline so that you have the most flexibility for optimizing battery life and getting updates for your specific application If you want temperature updates you should only select one of these association groups to send to a particular device Caution More frequent notification will de...

Страница 4: ...onable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful inte...

Страница 5: ...claims all implied warranties including but not limited to the implied warranties of merchantability and fitness for a particular purpose FORTREZZ LLC does not warrant guarantee or make any representations regarding the use or the results of the use of the products or any accompanying materials in terms of their correctness accuracy reliability or otherwise In no event shall FORTREZZ LLC be liable...

Страница 6: ... COMMAND_CLASS_WAKE_UP COMMAND_CLASS_BATTERY COMMAND_CLASS_CONFIGURATION Configuration Command Class Parameters PARA METER DESCRIPTION DEFAULT VALUE SIZE bytes POSSIBLE VALUES 1 Temperature low threshold 0x04 4 C 1 0xF6 0x45 10 69 C 2 Temperature high threshold 0x46 70 C 1 0xF7 0x46 9 70 C 3 Water Alarm Mode can only be set in the FTS05P cannot be changed in the FTS05 always returns 0 for water de...