FortrezZ FTS05 Скачать руководство пользователя страница 1

FTS05 / FTS05P - Wireless Flood and  
Temperature Sensor, User Manual  

 

 

 

www.fortrezz.com 

 Made in USA 

060717

  

 

INTRODUCTION 

The FTS05x sensor is a Z-WavePlus

TM 

Security-enabled device that detects water leaks and measures temperature.  In case of leak or high/low 

temperature conditions it will send alerts on your Z-Wave

TM 

network.  The FTS05x is compatible with other Z-Wave

TM

 and Z-WavePlus

TM

 certified 

products.  

The FTS05x sensor comes in four part numbers for each geographic region (where ‘yy’ b

elow indicates, for example, US or EU): 

 

FTS05LB-yy and FTS05LW-yy (Battery only version with black and white cases) 

 

FTS05PLB-yy and FTS05PLW-yy (Battery/AC version with water/temperature probe and black and white cases) 

For the latest User Manual, go to www.fortrezz.com 
 

SPECIFICATIONS 

Power:  

Two AA alkaline batteries (and AC Adapter, FTS05P version) 

Battery Life: 

Calculated to be 1 to 2 years depending on battery capacity/quality and no alarms and default Z-Wave network settings

 

Frequency Range: 

908.4MHz (US);   868.4MHz (EU) 

Distance Range: 

Max 100ft line of sight in unobstructed environment 

Enclosure Size (LxWxD): 

3" (76 mm) x 2.1" (53mm) x 1.1" (30mm)

 

Weight: 

0.25 lb (110 g)

 

Operating Temperature: 

-

10⁰C (14F) to +70⁰C (158F)

 

 

 

WARNINGS AND PRECAUTIONS 

 

Do not store highly flammable items such as oily rags or other combustibles near your FTS05x.  

 

Do not apply electrical power to the unit unless the unit is fully assembled.  

 

Install unit in accordance with electrical codes and regulations. In case you are unsure about any parts of these instructions consult an 
electrician or Z-Wave

TM

 home automation specialist. 

 

FTS05x functionality is based on wireless (RF) transmissions.   Any wireless transmission can be subject to RF interference or loss of 
communication.  This interference or loss of communication may cause the unit to not operate as intended.  You, the end-user, are 
responsible for ensuring that the FTS05x functionality and installation meets your desired requirements. 

o

 

WARNING - The FTS05x must not be used in life support and / or safety applications. 

 

Do not place FTS05x on or near metal objects. This decreases range and/or blocks wireless transmissions.   

 

Information provided in this manual is for your convenience and may be superseded by updates.   This manual is subject to change 
without notice.   It is your responsibility to ensure that the FTS05x functionality meets your needs and specifications. 

 

Using the FTS05x in a Z-Wave

TM

 Network

  

 
Program Switch for Network Add/Remove  

The switch is used for adding into or removing from a Z-Wave

TM

 

network.  Refer to your controller’s User Manual for specific

 details.  A Security-Enabled controller must be 

used to fully utilize the FTS05x. 

 

Add 

(Inclusion) into a network: 1) Set up the Add/Inclusion mode at the controller; 2) Briefly press the switch once and the controller will indicate 

the unit has been added into the network.  Also, the LED will blink when complete.  Add/

Inclusion and Remove/Exclusion are always done at normal 

transmit power mode. This product can be added and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers 
and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the 
network.  

The FTS05x can be added either securely (ZWave S0 Security) or non-securely depending on your controller settings. 

Remove 

(Exclusion) from a network: 1) Set up the Remove/Exclusion mode at the controller; 2) Press and hold the switch for approx. 2 seconds 

and then release.  The controller will indicates the unit has been removed from the network.  The LED will blink when complete. 

Associations:  

Once in a network, a controller can be used to associate the FTS05x with other devices in the Z-Wave

TM

 network, such as a light or 

a remote audible alarm. 

Refe

r to your controller’s documentation on how to associate 

FTS05x with another device in your network.

 The FTS05x 

supports eight association groups with a maximum of 2 devices in each group.  Refer to the Association section below. 

Node Info / Keep-Alive:

  While not in a network, the FTS05x will send the Z-Wave

TM

 Node information frame when the switch is briefly pressed.  

This is primarily used for adding as described above.  The node information frame will also be sent while in network when the switch is pressed 
and  held  for  2  seconds.    In  either  case,  the  FTS05x 

will  ‘stay  awake’  for  approximately  30  seconds  after  this  to  allow  time  for  configuration 

commands from the controller.  Refer to Status indications below for LED feedback.   

Wakeup Notification:

 The FTS05x will wake up and send a notification every 4 hours (default) to allow a controller to query and update the status 

of the unit.   A brief switch press while in network will also cause the FTS05x to wake up and send a notification.  The device stays awake for 10 
seconds during this time or longer if communicating with the controller. 

Содержание FTS05

Страница 1: ...ts your needs and specifications Using the FTS05x in a Z WaveTM Network Program Switch for Network Add Remove The switch is used for adding into or removing from a Z WaveTM network Refer to your controller s User Manual for specific details A Security Enabled controller must be used to fully utilize the FTS05x Add Inclusion into a network 1 Set up the Add Inclusion mode at the controller 2 Briefly...

Страница 2: ...ciation Basic Set messages and Alarm alert messages may be configured and sent Drying or submerging FTS05P only the sensor contacts will clear the Water Alarm If an over under temperature Alarm occurred and the temperature alarm conditions are no longer present an alarm clear message is also sent Also depending on your Z WaveTM controller it is possible to receive a remote alert For example with s...

Страница 3: ...y using the longest acceptable interval between temperature updates The temperature report was not included in the Lifeline so that you have the most flexibility for optimizing battery life and getting updates for your specific application If you want temperature updates you should only select one of these association groups to send to a particular device Caution More frequent notification will de...

Страница 4: ...onable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful inte...

Страница 5: ...claims all implied warranties including but not limited to the implied warranties of merchantability and fitness for a particular purpose FORTREZZ LLC does not warrant guarantee or make any representations regarding the use or the results of the use of the products or any accompanying materials in terms of their correctness accuracy reliability or otherwise In no event shall FORTREZZ LLC be liable...

Страница 6: ... COMMAND_CLASS_WAKE_UP COMMAND_CLASS_BATTERY COMMAND_CLASS_CONFIGURATION Configuration Command Class Parameters PARA METER DESCRIPTION DEFAULT VALUE SIZE bytes POSSIBLE VALUES 1 Temperature low threshold 0x04 4 C 1 0xF6 0x45 10 69 C 2 Temperature high threshold 0x46 70 C 1 0xF7 0x46 9 70 C 3 Water Alarm Mode can only be set in the FTS05P cannot be changed in the FTS05 always returns 0 for water de...