5.

 

Wind direction button

 

Press the wind direction button to set the direction of the air deflector and activate the movement 

of the air defector. 

 

 

 

  will be flashed in cycle. Press again to deactivate it. 

Note: this function is invalid under shoes drying mode. 

   

6.

 

Speed button

 

Press the speed button to set the wind speed: high, medium, low. The wind speed icon “

” will be 

shown on the LCD display. The flash frequency indicates the wind speed. 

 

7.

 

Auto button

 

Press the auto button to run in automatic operation mode: 

RH > 60%: the compressor will run with high wind speed. 

60% ≥ RH > 55%: the compressor will run with medium wind speed. 

RH ≤ 55%: the compressor will stop and run with low wind speed.         

 

8.

 

Key lock 

 

Press  the  Up/Down  key  at  the  same  time  for  2  seconds  to  lock  all  the  keys.  The  key  lock  icon 

“      ”will be shown on the LCD display. Press the Up/Down button again to cancel the key lock 

function. 

 

9.

 

Memory Function 

 

Press the ON/OFF button to turn off the appliance, then press the ON/OFF button again to 

turn it back on: the dehumidifier will run by the mode set before shutdown; timer function is 

not applicable. 

 

Unplug directly or power cut, then reconnect the power supply again: the appliance will run 

by the mode set before shutdown; the timer setting will continue to run. 

If press the ON/OFF button to turn off and unplug the appliance, then reconnect the power supply 

again, the appliance will run as factory setting mode. 

 

PRECAUTIONS 

1.

 

The humidity setting should not be set higher than the ambient humidity to operation. 

2.

 

When the water tank is full or the water tank full indicator “

” turns on, drain the water, and install 

the empty water tank back to its position. The appliance can continue its operation. 

3.

 

After the power is off, wait for 3 minutes before restarting the appliance to protect the compressor. 

4.

 

The operational temperature range of this appliance is 5-35

o

C. 

5.

 

If  the  plug  and  power  supply  are  in  normal  condition,  and  the  dehumidifier  does  not  start,  please 

unplug to wait for 10 minutes and restart the appliance (as it takes around 10 minutes to reposition). 

If the appliance still does not start after 10 minutes, please contact the service center. 

6.

 

When  the  dehumidifier  is  in  operation,  the  running  compressor  will  get  hot  and  the  room 

temperature will be increased. This is normal. 

7.

 

The  built-in  defrosting  sensor  detects  room  temperature  and  will  cease  the  operation  of  the 

compressor  for  about  10  minutes  when  room  temperature  is  below  15

 o

C.  Defrost  indicator  “

” 

will be on when the appliance is in the function of defrosting. 

 

 

Содержание FDH2814

Страница 1: ...Dehumidifier User Manual Model FDH2814 Before operating the appliance please read this manual and all the safety instructions thoroughly and retain it for future reference...

Страница 2: ...CONTENT PAGE SAFETY INSTRUCTION 1 PARTS DESCRIPTION 2 CONTROL PANEL 2 OPERATION INSTRUCTION 3 MAINTENANCE INSTRUCTION 6 TROUBLESHOOTING 7 SPECIFICATION 8 WARRANTY 9...

Страница 3: ...iance when not in use Make sure the power is off before pulling out the plug Do not pull the cord 15 When the appliance is not in use for a prolonged period please turn it off unplug it pack it well a...

Страница 4: ...2 PARTS DESCRIPTION CONTROL PANEL Wind Direction Button Timer Button LCD Display Up Button Humidity Setting Button Mode Button ON OFF Button Speed Button Down Button Auto Button...

Страница 5: ...in 5 minutes after start up If the setting up humidity is 3 higher than the actual humidity the compressor will be stopped with the fan keep working If the setting up humidity is 3 lower than actual h...

Страница 6: ...liance will run by the mode set before shutdown the timer setting will continue to run If press the ON OFF button to turn off and unplug the appliance then reconnect the power supply again the applian...

Страница 7: ...pper Fig 1 3 Connect the drain hole with an 14mm inner diameter water tube Fig 2 Please purchase the water tube SHOES DRYING MODE INSTRUCTION 1 Span open the shoes drying outlet cover on the left of t...

Страница 8: ...the filter Cleaning the body 1 Use soft cloths to clean the appliance 2 Do not use volatile chemicals gasoline detergents chemically treated cloths or other cleansing solutions All these could possibl...

Страница 9: ...or outlet blocked up A Please move the object away from the air intake or outlet Q Is the room humidity already quite low A The dehumidifier shall not operate if the humidity setting is higher than th...

Страница 10: ...Frequency 220V 240V 50Hz Rated Power 370W At 30 80 RH Dehumidifying Capacity 28L day At 26 7 60 RH Dehumidifying Capacity 16L day Net Weight 15 8kg Dimension W x D x H mm 402 x 260 x 610 Temp range f...

Страница 11: ...ould be inserted into any extension unit or vice versa Stop using an adaptor or an extension unit or a socket if its socket holes cannot firmly hold a plug if it is too hard to insert a plug into it T...

Отзывы: