OPERATION INSTRUCTION
*Connect the power cord to the correct power supply (220-240V, ~50Hz).
1.
ON/OFF button
When the dehumidifier is plugged in, it will go into standby mode, and the power indicator will
begin to flash. Press the ON/OFF button to turn on the dehumidifier, and the power indicator will be
on. Press the ON/OFF button again to turn off the dehumidifier, and the power indicator will begin
to flash.
2.
Humidity setting
Press the Up/Down button to set the humidity (a range of CO, 30% to 80%.). After start-up, the
LED display will show the default value “CO”. Press the Up/Down button to change the value. For
each press, the set humidity will be increased / decreased by 5%. The LED display will show “CO”
and the dehumidifier will be operated continuously. The LED display will be returned to the room
humidity after 5 seconds, humidity setting will be completed.
Effect of humidity setting to operation state:
If the appliance is operated in continuous dehumidifying mode, its operation will not be
influenced by the change of ambient humidity.
If the appliance is operated in non-continuous dehumidifying mode, humidity control system
will be started in 5 minutes after start-up. If the setting-up humidity is 3% higher than actual
humidity, the compressor will be stopped, but the fan will keep working. If the setting-up
humidity is 3% lower than actual humidity, the compressor will be restarted.
3.
Timer button
Auto off timer (1-24 hours) can be set. Press the TIMER button, the timer indicator will begin to
flash, and the LED display will flash and show the setting-up time. Press the UP/DOWN button in 5
seconds to set the auto off timer. For each press, the set auto off time will be increased / decreased
by 1 hour. The LED display will be returned to the room humidity after 5 seconds, auto off timer
setting will be completed.
PRECAUTIONS
1.
The dehumidifier shall not operate if the humidity setting is higher than the ambient humidity.
2.
When the tank is full or the tank full indicator illuminates, drain the water, and install the empty
tank back to its position, so the appliance can continue its operation.
3.
After the power is off, wait for 3 minutes before restarting the appliance to protect the compressor.
4.
The operational temperature range of this appliance is 5-35
o
C.
5.
If the plug and power supply are in normal condition, the dehumidifier still does not start, please
wait for 10 minutes and restart the appliance (because it takes around 10 minutes to reposition). If
the appliance still does not start after 10 minutes, please contact the service agent for repair.
6.
When the dehumidifier is in operation, the running compressor will get hot and the room
temperature will be increased. This is normal.
7.
The built-in defrosting sensor detects room temperature and will cease the operation of the
compressor for about 10 minutes when room temperature is below 15
o
C. Defrost indicator will be
turned on when the appliance is in the function of defrosting.