To edit or delete the STA Interface:
1
Log on to the Bridge GUI through an
Administrator
-level
account and select
Configure
->
Radio Settings
from the
menu on the left.
2
If you are reconfiguring the existing
STA Interface
, on the
Radio
screen:
If you are reconfiguring one or more Advanced View
settings (see Table 3.8), click
ADVANCED VIEW
in the
upper right corner of the page. (If not, skip this step.)
Click the
EDIT
STATION
button.
In the
Radio
screen’s
Edit Station Mode
frame, enter
new values for the setting(s) you want to change
(described in sections 3.3.5.1 through 3.3.5.10, above).
Click
APPLY
in the upper right of the screen (or
CANCEL
your changes).
or
If you are deleting the
STA Interface
, on the
Radio
screen:
Click the
DELETE
STATION
button.
3.3.5.13
Enabling and Disabling ES210 Bridge Station Mode
Station Mode
is disabled by default, in which state the
preconfigured scanning interface used for network detection is
disabled. You must enable the function before you can
manually configure a
STA Interface
or scan for a network.
To enable or disable Station Mode:
If one or more BSSs have been configured on the ES210
Bridge radio, you must delete all BSSs before you can enable
Station Mode
(refer to Section 3.3.4).
If a
STA Interface
is present, you must delete it before you can
disable
Station Mode
1
Log on to the Bridge GUI through an
Administrator
-level
account and select
Configure
->
Radio Settings
from the
menu on the left.
2
Change the
Station Mode
state:
If you are enabling
Station Mode,
click the
ENABLE
STATION
button.
or
If you are disabling
Station Mode,
click the
DISABLE
STATION
button.
Station Mode
must be disabled on the ES210 Bridge radio,
before you can configure a BSS on the radio (refer to Section