Operating Instructions: ATOM

General Data

ATOM Product Type

Power-to-release  (unlock), Safety- on-Guard-Lock

-

ing

Power-to-release  (unlock), Safety- on-Guard

Power-to-Lock,  Safety-on-Guard

Housing Materials

Passivated and painted Zinc Alloy to BS12844 ZA3 and Stainless Steel to 

BS3146-2:1975 (ANC4B)

Mechanical Life

1,000,000 Switching Operations

Holding Force 

F

5 kN

8 kN

8 kN

Holding Force 

F

Zh

6 kN

9.2 kN

9.2 kN

Maximum Holding Force, 

F

1max

12 kN

12 kN

12 kN

Minimum Actuating Radius

150 mm (see fig.5) 

Maximum Actuating Frequency

720 Operations per Hour

Power-to-release (unlock) 

Safety-on-Guard-Locking (SOGL)

Power-to-release (unlock) 

Safety-on-Guard (SOG)

Power-to-Lock 

Safety-on-Guard (SOG)

The recommended set up for most 

machine guarding applications and 

ideal for machines with run-down times.  

The Device unlocks when power 

supplied. Safety circuits change state 

when the device locks or unlocks.

Popular configuration for where the 

solenoid performs a process control 

function rather than a safety function. 

The Device unlocks when power 

supplied. Safety circuits change state 

when actuator is engaged or removed.

When power is supplied to the solenoid 

the device becomes locked.

Allows for faster access and exit in the 

event of a power failure or power off 

event.

Safety circuits change state when 

actuator is engaged or removed.

Part No.

Solenoid  

Locking Type

Switch Configuration

M12 Connector Types

Optional 

Escape 

Release

ATM-100A1-A

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

Single 5 Pin M12

No

ATM-100A2-A

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

2 x 5 Pin M12 in

‘Daisy-Chain’ configuration

No

ATM-100A3-A

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

Single 8 Pin M12

No

ATM-100A4-A

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

2 x 5 Pin M12

No

ATM-110A1-A

Power-to-release (unlock) Safety-on-Guard (SOG)

Single 5 Pin M12

No

ATM-110A2-A

Power-to-release (unlock) Safety-on-Guard (SOG)

2 x 5 Pin M12 in 

‘Daisy-Chain’ configuration

No

ATM-110A3-A

Power-to-release (unlock) Safety-on-Guard (SOG)

Single 8 Pin M12

No

ATM-110A4-A

Power-to-release (unlock) Safety-on-Guard (SOG)

2 x 5 Pin M12

No

ATM-610A1-A

Power-to-Lock

Safety-on-Guard (SOG)

Single 5 Pin M12

No

ATM-610A2-A

Power-to-Lock

Safety-on-Guard (SOG)

2 x 5 Pin M12 in 

‘Daisy-Chain’ configuration

No

ATM-610A3-A

Power-to-Lock

Safety-on-Guard (SOG)

Single 8 Pin M12

No

ATM-610A4-A

Power-to-Lock

Safety-on-Guard (SOG)

2 x 5 Pin M12

No

ATM-100A1-A-ER1

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

Single 5 Pin M12

Yes

ATM-100A2-A-ER1

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

2 x 5 Pin M12 in 

‘Daisy-Chain’ configuration

Yes

ATM-100A3-A-ER1

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

Single 8 Pin M12

Yes

ATM-100A4-A-ER1

Power-to-release (unlock) Safety-on-Guard-Locking (SOGL)

2 x 5 Pin M12

Yes

2

Содержание ATOM

Страница 1: ... invalidates all warranties The Device must be installed in electrical installations meeting the requirements of the applicable IEC standards The Device is not to be used as a Mains Isolator or Emergency Stop The Device is a component to be added to a permanent electrical installation meeting the requirements of the applicable IEC EN standards All the voltages used within the connected circuits mu...

Страница 2: ...uator is engaged or removed Part No Solenoid Locking Type Switch Configuration M12 Connector Types Optional Escape Release ATM 100A1 A Power to release unlock Safety on Guard Locking SOGL Single 5 Pin M12 No ATM 100A2 A Power to release unlock Safety on Guard Locking SOGL 2 x 5 Pin M12 in Daisy Chain configuration No ATM 100A3 A Power to release unlock Safety on Guard Locking SOGL Single 8 Pin M12...

Страница 3: ...thstand Voltage Uimp 500V Voltage Drop Ud 3 5V Rated Operating Currents 400mA Minimum Operational Current 100mA Off State Current 0 5mA Rated Conditional Short circuit Current 100 A Overvoltage Category Type 2 Electromagnetic Compatibility EMC Conforms to BS 60947 5 3 To Meet UL Requirements The device must be connected to a Limited Voltage Current Circuit A 4A fuse must be fitted to the device po...

Страница 4: ...TOM_PIN_OUT_INFO DATE 17 03 22 THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE DISCLOSED TO ANY 3rd PARTY WITHOUT OUR SPECIFIC WRITTEN APPROVAL ATOM CONNECTOR PIN OUT INFORMATION RELEASE LEVEL Approved for Production TITLE SCALE 2 00 ISSUE 0 A ATOM CONNECTOR POSITIONS 4 5 3 1 2 SINGLE 5 PIN M12 CONNECTOR ATM 100A1 A ATM 1...

Страница 5: ...ened For Safety on Guard SOG devices the monitors is activated when the device is unlocked Daisy Chain information The number of devices that can be wired in series depends on two main criteria 1 Power line voltage drop 2 Total Safety Response Time Voltage Drop Safety Response Time Each ATOM Device in series draws current and causes a voltage drop on the power line The greater the number of device...

Страница 6: ...acing the Device into its Locked State Unlocking The Device is unlocked when voltage is applied to the Solenoid Drive pin Opening Once unlocked the ATOM Actuator assembly can be removed from the ATOM Switch assembly Auxiliary Release Function In the event of power failure the ATOM Interlocking Device can be released and unlocked using the supplied Auxiliary Release Driver Bit irrespective of the s...

Страница 7: ...housing M12 cable s entry Manual solenoid override To reset and relock an ATOM Interlocking Device after an Escape Release operation First isolate power to the guarded machine to ensure it cannot restart when Safety Outputs go high Pull on Escape Release knob see Fig 1 Close the Gate Door of the guarded area Test that the Escape Release has been fully reset by checking status of Safety Outputs are...

Страница 8: ... on actuator Check for any obstruction of the mechanism Press actuator tightly towards the device to release any tension Low High Amber Flash Safety Input Fault Mismatch between two safety input signals Confirm continuity from the previous device on both safety inputs then reset fault by cycling the safe state of the previous device Low Low 2 Amber Flash Safety Output Fault Short circuit on safety...

Страница 9: ... Door Gate post to allow for Escape Release housing See Fig 10 for required hole location Note ATOM with Escape Release ER suitable for door gate post thickness up to 56mm For anything greater than 56mm an extension kit will be required please contact Fortress for more information 6 Mount the ATOM Switch and ATOM Actuator assemblies to appropriate parts of the machine or guarding The ATOM Actuator...

Страница 10: ...ly M12 quick disconnect cable s M5 nylon washer M5 security fixing screw min length 45mm M5 security fixing screw min length 45mm Figure 3 Extrusion Profile Mounting Application Example M12 quick disconnect cable s essinterlocks com rtress erlocks M5 security fixing screw min length 20mm M5 T Nut M5 T Nut ATOM actuator assembly M5 security fixing screw min length 20mm M5 T Nut M5 T Nut 40mm alumin...

Страница 11: ...embly ATOM actuator assembly 11 Figure 5 ATOM Device with Escape Release Mounting Example www fortress safety com FORTRESS ATOM Escape Release knob removed while mounting Escape Release housing mounted through gate post Ø 21mm min bore to accept Escape Release housing M5 T Nut M5 Nylon Washer M5 Security Fixing Screws min length 40mm M5 Nylon Washer M5 Security Fixing Screws min length 40mm M5 T N...

Страница 12: ...e Escape Release knob see fig 1 and remove the ATOM Actuator from the ATOM Switch 5 Pull on Escape Release knob to reset Escape Release 6 Reinsert the ATOM Actuator into the ATOM Switch It must lock into position Power to Lock ATOM Interlocking Devices 1 Insert the ATOM Actuator into the ATOM Switch It must not lock into position Electrical Function Test Powered 1 Close the guard ensure the ATOM D...

Страница 13: ...is Voided Under the Following Conditions 1 If these instructions are not followed 2 Non compliance with safety regulations 3 Installation and electrical connection not performed by authorised personnel 4 Non implementation of functional checks 13 Actuator Does Not Enter Head Correcting A Rolled Mechanism In some scenarios such as cleaning or high vibration the ATOM Interlocking Device can have the...

Страница 14: ...R S Protection Against Environmental Influences In order to maintain full mechanical and electrical performance the Device must be protected against the ingress of all foreign bodies such as swarf sand blasting shot etc The Device is not suited for use in corrosive environments The Device is only suitable for dusty environments where careful consideration has been given to environment requirements...

Страница 15: ... Dimensional Drawing ATOM Interlocking Device 6 7 7 138 25 13 8 72 5 32 16 6 75 41 5 5 THRU ALL 2 PLACES 33 2 36 125 5 5 125 20 16 6 5 2 THRU ALL 2 PLACES 5 2 THRU ALL 2 PLACES 40 WHEN CENTRALLY ALIGNED 6 0 15 0 7 7 THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC WRITTEN APPROVA...

Страница 16: ...ngth Description CABLE 2M AT1 2m To suit 5 Pin M12 connectors CABLE 5M AT1 5m CABLE 10M AT1 10m CABLE 2M AT3 2m To suit 8 Pin M12 connectors CABLE 5M AT3 5m CABLE 10M AT3 10m CABLE 2M ATD 2m To suit X 5 Pin M12 daisy chain connectors CABLE 5M ATD 5m CABLE 10M ATD 10m ATOM Shorting Plug Part No Description SHORTING PLUG ATD To terminate last ATOM Device at end of daisy chain FORTRESS A company Halm...

Отзывы: