Page 4

For technical questions, please call 1-888-866-5797.

Item 57336 

        

SA

FE

TY

OP
ERA

TI

O

N

MAINT

ENANC

E

IN

ST

ALLA

TI

O

N

a.  Make sure your extension cord 

is in good condition.

b.  Be sure to use an extension cord which 

is heavy enough to carry the current your 

product will draw.  An undersized cord will 

cause a drop in line voltage resulting in loss 

of power and overheating.  Table A shows the 

correct size to use depending on cord length 

and nameplate ampere rating.  If in doubt, 

use the next heavier gauge.  The smaller 

the gauge number, the heavier the cord.

15. Industrial applications must follow OSHA guidelines.

16. Maintain labels and nameplates on the 

compressor.  These carry important safety 

information.  If unreadable or missing, contact 

Harbor Freight Tools for a replacement.

17. This product is not a toy.   

Keep it out of reach of children.

18. People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 

close proximity to heart pacemaker could cause 

pacemaker interference or pacemaker failure.

 SAVE THESE INSTRUCTIONS.

Grounding

TO PREVENT ELECTRIC SHOCK AND DEATH  

FROM INCORRECT GROUNDING WIRE CONNECTION: 

Check with a qualified electrician if you are in doubt as to whether the outlet is 

properly grounded.  Do not modify the power cord plug provided with the compressor.  

Never remove the grounding prong from the plug.  Do not use the compressor if the power cord or plug 

is damaged.  If damaged, have it repaired by a service facility before use.  If the plug will not fit the outlet, 

have a proper outlet installed by a qualified electrician.

110-120 VAC Grounded Compressors: Compressors with Three Prong Plugs

1.  In the event of a malfunction or breakdown, 

grounding provides a path of least resistance for 

electric current to reduce the risk of electric shock.   

This compressor is equipped with an electric 

cord having an equipment-grounding conductor 

and a grounding plug.  The plug must be 

plugged into a matching outlet that is properly 

installed and grounded in accordance 

with all local codes and ordinances.

2.  Do not modify the plug provided –  

if it will not fit the outlet, have the proper 

outlet installed by a qualified electrician.

3.  Improper connection of the equipment-grounding 

conductor can result in a risk of electric shock.  

The conductor with insulation having an outer 

surface that is green with or without yellow 

stripes is the equipment-grounding conductor.  

If repair or replacement of the electric cord or 

plug is necessary, do not connect the equipment-

grounding conductor to a live terminal.

4.  Check with a qualified electrician or service 

personnel if the grounding instructions are 

not completely understood, or if in doubt as to 

whether the compressor is properly grounded.

5.  Use only 3-wire extension cords that have 

3-prong grounding plugs and 3-pole receptacles 

that accept the compressor’s plug.

6.  Repair or replace damaged or 

worn cord immediately.

Grounding 

Pin

125 VAC 3-Prong Plug and Outlet

(for up to 125 VAC and up to 15 A)

7.  This compressor is intended for use on a 

circuit that has an outlet that looks like the one 

illustrated above in 

125 VAC 3-Prong Plug 

and Outlet

.  The compressor has a grounding 

plug that looks like the plug illustrated above 

in 

125 VAC 3-Prong Plug and Outlet

.

8.  The outlet must be properly installed and grounded 

in accordance with all codes and ordinances.

9.  Do not use an adapter to connect this 

compressor to a different outlet.

Содержание 57336

Страница 1: ...ence 21l When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2021 by Harbor Freight Tools All...

Страница 2: ...tions for future reference The warnings precautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be understood by th...

Страница 3: ...the compressor for operations different from those intended could result in a hazardous situation 5 Service a Have your compressor serviced by a qualified repair person using only identical replaceme...

Страница 4: ...sors with Three Prong Plugs 1 In the event of a malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This compressor is equi...

Страница 5: ...ard conditions NPT National pipe thread tapered NPS National pipe thread straight Double Insulated V Volts Alternating Current A Amperes Specifications Electrical Rating 120VAC 60Hz 15A Air Outlet Siz...

Страница 6: ...use of this product TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch OFF and unplug the Air Compressor from its electrical outlet before assembling or making any adjustments t...

Страница 7: ...ower Cord 4 Turn the Power Switch ON AUTO 5 Let the unit run for 30 minutes Air will expel freely through the Drain Valve 6 Turn the Power Switch OFF 7 Unplug the Power Cord and close Drain Valve Air...

Страница 8: ...A Air Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Couple...

Страница 9: ...r vibration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point o...

Страница 10: ...ons are air tight the extra air leaking out will cause the compressor to operate too often increasing wear on the compressor Note As long as the Power Switch is ON AUTO the operation of the Air Compre...

Страница 11: ...e damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use Cleaning Maintenance and Lubrication 1 BEFORE EACH USE inspect the general condition of the air...

Страница 12: ...to open it Tilt Compressor forward to drain 4 When all the pressure and moisture are released close the Drain Valve Air Filter Maintenance 1 Remove Air Inlet Filters by turning them counterclockwise 2...

Страница 13: ...ARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTR...

Страница 14: ...3 Bolt M4 8 6 44 Cylinder Head Seal 2 45 Cylinder Cap 2 46 Washer 8 47 Spring Washer 8 48 Bolt M6 70 8 49 T Cock 1 50 Easy Start Valve 1 51 Seal 4 52 Tube 2 Part Description Qty 53 Cylinder Head Guard...

Страница 15: ...Page 15 For technical questions please call 1 888 866 5797 Item 57336 SAFETY OPERATION MAINTENANCE INSTALLATION Assembly Diagram...

Страница 16: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Отзывы: