Fortinet FortiADC 1200F Скачать руководство пользователя страница 12

23

22

Verlassen einer BATTERIE in einer extrem hohen Umgebungstemperatur, die zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder 
Gas führen kann

Eine BATTERIE, die einem extrem niedrigen Luftdruck ausgesetzt ist, der zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder 
Gas führen kann.

CAUTION: Shock Hazard. Disconnect all power sources.
ATTENTION: Risque d'électrocution. Débranchez toutes les sources d'alimentation.

Caution

: Slide/rail mounted equipment is not to be used as a shelf or a work space.

Attention:

 Un équipement monté sur bâti ne doit pas être utilisé sur une étagère ou dans un espace de travail.

Warning: Stability hazard.
Aviso: Perigo de estabilidade.

The rack may tip over causing serious personal injury.
O rack pode tombar causando ferimentos graves.

Before extending the rack to the installation position, read the installation instructions.
Antes de estender o rack para a posição de instalação, leia as instruções de instalação.

Do not put any load on the slide-rail mounted equipment in the installation position.
Não coloque nenhuma carga no equipamento montado em trilho deslizante na posição de instalação.

Do not put any load on the slide-rail mounted equipment in the installation position.
Não coloque nenhuma carga no equipamento montado em trilho deslizante na posição de instalação.

Do not leave the slide-rail mounted equipment in the installation position.
Não deixe o equipamento montado em trilho deslizante na posição de instalação.

Regulatory Compliance

Federal Communication Commission (FCC) – USA

This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits are 
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment 
generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful 
interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be 
required to correct the interference at his own expense.

WARNING:

 Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to 

operate the equipment.

Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada

CAN ICES-003 (A) / NMB-003 (A)

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regula¬tions of the 
Canadian Department of Communications.

Cet appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le 
Règlement sur le brouillage radioélectrique édicte par le ministère des Communications du Canada.

European Conformity (CE) - EU

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate 
measures. 

Voluntary Control Council for Interference (VCCI) – Japan

この装置は、クラスA機器です。この装置を住宅環境で使用すると電波妨害を引き起こすことがあります。この場合には
使用者が適切な対策を講ずるよう要求されることがあります

VCCI-A

Product Safety Electrical Appliance & Material (PSE) – Japan

日本では電気用品安全法(PSE)の規定により、同梱している電源コードは本製品の専用電源コードとして利用し、他の製品に使用しないでください。

Bureau of Standards Metrology and Inspection (BSMI) – Taiwan

The presence conditions of the restricted substance (BSMI RoHS table) are available at the link below: 
限用物質含有情況表 (RoHS Table) 請到以下 網址下載:
https://www.fortinet.com/bsmi

警告: 為避免電磁干擾,本產品不應安裝或使用於住宅環境。

請仔細閱讀以下說明
本設備勿置於潮濕處。
連接至電源前,請先檢查電壓。

當設備不用時,請將所有電源線拔除,避免電壓不穩而造成傷害。
勿將任何液體濺入設備中,避免線路短路。
基於安全理由,只有受到專業訓練的從業人員,才可以打開本設備。
請勿自行調整或修理已通電的設備,以確保您的安全。
如不小心受傷,請立刻找急救人員給予您適當的救護,千萬別因傷勢輕微而忽略自己的傷勢。

請依照台灣法規處置電池。
若不正確替換電池可能導致爆炸危險,替換電池時,請使用設備生產商推薦使用的電池。
請勿拆卸、刺穿或以其他方式損壞電池。

雷射設備非用戶維修設備,請與生產商聯繫維修事宜。

注意: 要斷開電源,請將所有電源線從本機上拔下

英屬蓋曼群島商防特網股份有限公司台灣分公司
地址:台北市內湖區行愛路176號2樓
電話:(02) 27961666

China

此为A级产品,在生活环境中,该产品可能会造成无线电干扰。这种情况下,可能需要用户对其采取切实可行的措施。

Содержание FortiADC 1200F

Страница 1: ...FortiADC 1200F QuickStart Guide ...

Страница 2: ...nding commitment by Fortinet and Fortinet disclaims all warranties whether express or implied except to the extent Fortinet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified performance metrics and in such event only the specific performance metrics expre...

Страница 3: ...ement default IP is 192 168 1 99 HA RJ45 GE high availability port Ports 17 to 24 SFP 10 GE GE SFP slots Ports 9 to 16 SFP GE SFP slots Ports 1 to 8 RJ45 GE SFP slots Green Link established at 10 or 1 Gbps Flashing Green Transmitting data Off No link established 1 Power Supply Alarm Amber Power supply failure Off Normal operation System LED Indicators Power Supply Fan Alarm Amber Fan failure Off N...

Страница 4: ...50 60Hz Redundant Power Supplies x2 48V DC to 60V DC 20A Power Switch turns the power ON OFF Power Switch turns the power ON OFF 4 2 2 3 3 1 1 Green Power supply operating normally Flashing Green 1 sec AC input but in Active Standby mode Amber AC input power failure second power supply operating normally Off No AC input DC Power Supply Indicator 4 Green PSU operating normally Flashing Green 1 sec ...

Страница 5: ... Installation Plug in your device to a power outlet using the provided DC power cables Assemble the power cables using the supplied power connector Pin 1 Pin 2 Pin 2 Pin 3 Pin 1 Pin 3 DC PSU1 DC PSU2 Note Pin 1 is Negative Pin 2 is Positive Pin 3 is Ground Cables and terminal lugs are not included The wires are rated between 24 10 AWG Note We recommend connecting your FortiADC to an uninterruptibl...

Страница 6: ...sliding out ensure that it is locked when installing the appliance Prevent Electrostatic discharge ESD damage by wearing antistatic devices Do not place heavy objects on the appliance What You Will Need Philips screwdriver level tape measure Rack provided cage nuts and screws A lifting device or additional support ESD antistatic gear https video fortinet com http support fortinet com Rail Assembly...

Страница 7: ...he remaining inner rail Align Rail Metal Clip Inner Rail Inner Rail Attach the Outer Rails to the Rack Front Outer Rail 1 Place an outer rail against a side of the rack 2 Align the front outer rail with the front of the rack 3 Push the front outer rail mounting pins into the rack post holes 4 Lock the locking latch to safely secure the front outer rail to the post Rear Outer Rail 5 Extend the rear...

Страница 8: ... is a stop System Lock 6 Apply even pressure and slide the release tabs outward while sliding the appliance all the way into the rack until the system release tabs click and lock into position 7 Use four rack screws not provided to secure the appliance to the rack System Release Button Inner Rail Metal Clip Release Tab System Lock Out Tab Release Tab System Lock Out Tab System Lock Out Tab Release...

Страница 9: ... Local Setup An easy to use GUI compatible with most web browsers To minimize scrolling the screen resolution should be at least 1280 x 1024 pixels A B Ethernet Cable 1 Connect Port 1 to the Management Computer using the supplied Ethernet cable 2 Enable DHCP or set the Management Computer s IP and subnet to Static IP Address 192 168 1 1 Subnet Mask 255 255 255 0 3 Visit 192 168 1 99 in a web brows...

Страница 10: ...ic Settings Please refer to the admin guide found on docs fortinet com for detailed instruction on configuring your FortiADC Basic Network Settings 1 Once you have installed your FortiADC and configured your management interface we recommend setting the following Administrative password System time and date Network interfaces DNS 2 Test the connectivity between devices 3 Register your product if y...

Страница 11: ...tif assurant une protection contre les courts circuits et le câblage Ainsi il est recommandé de tenir compte du numéro d identification de l équipement Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Fiabilité de la mise à la terr...

Страница 12: ...pment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inte...

Страница 13: ...Fortinet com ...

Отзывы: