Converter  RS-BL  

                                                                             

      Manual       

 

 

 

 

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

         2016 

 

 

Содержание RS-BL

Страница 1: ...JSC FORTEZA FORTEZA RS BL Please visit our internet sites www forteza com or www forteza eu Page 1 Converter RS BL Manual 2016 ...

Страница 2: ...roperability with the FMC series detectors devices and Tribo M detector over the wire communication line only A personal computer PC or an Android based device may be used as the control panel 1 1 2 The converter consists of two independent converters Converter RS 485 in a USB hereinafter referred to as RS ensuring the connection of the detector to the PC or Android device over the wire communicat...

Страница 3: ...cal characteristics of the BL are stated in Table 1 2 Table 1 2 The technical characteristics of the BL No Characteristic Meaning 1 Power supply voltage 3 6 internal accumulator 8 30 V external source 2 Consumption current no more than 80 mА 3 Battery capacity no less than 850 mA per hour 4 The time of operation of the transformer from fully charged battery no less than 8 hrs 5 Battery charge time...

Страница 4: ...kage 1 Technical certificate 1 1 4 Installation and operation 1 4 1 The converter s operation principle The RS converter converts the electrical and time based characteristics of the RS 485 interface into the signals of the universal consecutive bus of the USB The BL converter transforms the electrical and time based characteristics of the RS 485 interface into signals of the Bluetooth wireless pe...

Страница 5: ...FORTEZA JSC FORTEZA RS BL Please visit our internet sites www forteza com or www forteza eu Page 5 ...

Страница 6: ...n to Bluetooth The proper power supply to BL is indicated by periodic synchronous flashings of both indicators in case of absence of exchange along the respective lines During the battery s discharge the RS and BL indicators are lighted in succession 2 1 5 The CHG light indicator of the charging device the red indicator reflects the state of the battery during the charging if the light is constant...

Страница 7: ...l source of 8 30 V The external source must be connected to the terminals and 2 2 4 For connecting the control panel to the detector with the help of wire connection it is necessary to do the following Connect the FMC RS cable it is applied in a set to the RS converter s terminals a b a red wire a black b Connect the plug of the FMC RS cable to the detector s RS 485 socket Connect the micro USB US...

Страница 8: ... the converter if The product is mechanically or thermally damaged or filled with water The failures caused by operational parameters set out in this manual failure to comply Send complaints to the following address JSC Forteza Tilzes str 38 91112 Klaipeda Lithuania Tel 370 46 411353 Fax 370 46 412231 E mail forteza forteza com ...