16
8.5.1 Place the RC Rx at the guard station. If several RC Rxs are placed at the guard station, they
must not be installed at the distance less than 2-3m from each other because it can cause the reduction of
the reception range.
8.5.2 If the distance between Rc Rx and a protective sector does not exceed 200 m, use a spike
antenna from the RC Rx set (see fig. 6.3). Take the antenna out the bag pocket and connect it to
“
АНТЕННА
” plug-and-socket (antenna plug-and-socket).
8.5.3 The installation place of RC Rx with a spike antenna should be chosen experimentally in order
to provide reliable receipt of alarms from all protective sectors of the system. RC Rx should be placed
vertically with the antenna upwards, at the maximum distance from the wiring lines and heavy metal
objects (lock boxes, shelves, heating pipes, grids, etc.), and at the distance 0,5 m minimum from
reinforced-concrete ceiling floor or wall.
8.5.4 Open the side hole of the bag and set the switch “
ПИТАНИЕ
” (supply switch) to “
ВКЛ
”
position (“ON” position). If all the system sectors are in standby mode, an audio signal is ON and “-“
sign is shown on the digital display.
8.5.5 Fasten the side hole. RC Rx is ready for operation both in stationary and portable variants.
8.5.6 If the distance from RC Rx to the protective sector is over 200 m , use a remote antenna, the
length of the antenna cable is 6m.
8.5.7 Mount the remote antenna in the following way:
- mount antenna 5 on upper elbow 1 (see fig. 6.5);
- connect upper elbow with two central elbows 2, then with lower elbow 3;
- mount this mast on pole 4, fix it using a hook on lower elbow 3;
- hang bag-counterweight 7 on hook 6, previously fill it with heavy objects (stones, sand, metal
details, etc,). Its weight must be 5 kg minimum. The bag is hanged with metal ring 8.
8.5.8 RC Rx is not recommended to be mounted near, inside and on large metal constructions, nearer
than 1 – 3 m from power lines, metal tubes, radio noise sources.
8.6 Connection of RC Rx to the Charger
8.6.1 Connect a socket of a cable of accumulator charge of any charger channel to one of the RC Rx
“
ЗАРЯД
БАТАРЕИ
” (battery charge) plug-and-sockets to use a charger as a stationary power supply
source of RC Rx. “
ПИТАНИЕ
” (power supply) switch of RC Rx must be in “
ВКЛ
” position (“ON”
position).
Attention!
If it is necessary to switch off a charger, first disconnect RC Rx from a charger to prevent
RC Rx accumulator discharge via a charger.
8.7 Connection of RC Rx to DADS
8.7.1 RC Rx is connected to DADS via “
ВЫХОД
НА
ССОИ
” (OUTPUT TO DADS) plug-and-
socket of RC Rx using a system DADS cable. The purpose of “
ВЫХОД
НА
ССОИ
” (OUTPUT TO
DADS) plug-and-socket studs are given in table 8.1.