![fortessa FTDEAH Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/fortessa/ftdeah/ftdeah_instruction-manual_2321467006.webp)
4
B, Cable to door stations/modules
RVV2x1.0
(
AWG18
)
2
mm
Part 2 Connection
2.1 Cable requirements:
A, Cable from door station to modules/ indoor phones
RJ45 Port
CAT-5/E cable
Please follow TIA/EIA-568B Standard for CAT-5(E) cables to avoid interference.
Wires
Type(size)
Distance
Wire resistance
Door station to module
Modules to indoor phones
FTP-5E(1.5)
UTP-5(0.75)
RVV(2X1.0)
≤
50m
≤
10
Ω
≤
10
Ω
<
30m
2.2 Cables and distance
30m
<
Min. gap:
≥
50cm, between low voltage and high voltage.
2.3
Terminals
EXT
KEY
12V
G
DATA
SW21
SW22
SW23
SW24
ADDR0
ADDR1
ADDR2
ADDR3
⑦
12V
+
12V
-
DATA
ALM
G
UL
G
①
COM
NC
NO
12V+ 12V- L+ L-
Jp3
JP1
JP2
Jp4
JP8
Jp6
JP51
JP21
12V- AU 32VIN V-
12V+ SGND ETRXD V+
R- T+ A+ VM-
R+ A- T- VM+
POWER UNLOCK
②
③
④
⑥
A, Door station Model FTDEPC4
B, Assistant door panel Model FTDEP4, FTDEP8
①
RJ45 port to isolation module.
②
Standby
.
③
Terminals to power supply & e-lock(power type).
④
Terminals to e-lock (signal type).
⑤
⑥
⑦
Terminals to EXIT push button.
Terminals between door station FTDEPC4 and assistant door panels.
Jumper couplers for coding assistant door panels.
Power supply to modules
Module
to
next
module
FTP-5E(1.5)
<
40m
(Please see details in 3.3.)
≤
10
Ω
⑤
⑥
Содержание FTDEAH
Страница 1: ...MULTIWAY 2 12 WAY DOOR ENTRY SYSTEM FTDEVM2 12 Instruction Rev01 ...