Epsilon-8100 User Manual Revision A.3
www.diamondsystems.com
Page 12
6. COMMAND LINE INTERFACE
The command line interface (CLI) is a modal, line-based interface with no screen editing features where
commands are executed immediately upon end-of-line. The CLI can be accessed directly via the serial
connection. The user must log in before CLI commands can be executed.
6.1 Making an Initial Connection
Serial line configuration:
38400 baud
8 bit data
No parity
1 stop bit
Login information
Username: admin
Password: {none}
The board is shipped with an IP address of 192.168.1.60. This allows the WEB interface to be accessed at that
address.
The IP address, mask and gateway must be set according to your environment, or you can enable IP and DHCP
if your environment includes a DHCP server. For example:
# configure terminal
(config)# interface vlan 1
(config-if-vlan)# ip address dhcp
(config-if-vlan)# end
Below example depicts configuration of static IP address,
# configure terminal
(config)# interface vlan 1
(config-if-vlan)# ip address 192.168.1.60 255.255.0.0
(config-if-vlan)# end
Display the IP address to confirm:
# show ip interface brief
Vlan Address Method Status
---- -------------------- -------- ------
1 192.168.1.60 Manual UP
#
6.2 Login/Logout Procedures
To get access to the CLI you must login by entering a username and password. You will automatically be queried
about the password.
The password is configurable. You may logout at any time and at any context level using the exit command