![Fortador Pro Plus Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/fortador/pro-plus/pro-plus_operating-manual_2320571032.webp)
32
If the burner is in the blocked mode, it will be indicated by non-flashing red colour
of the LED at the back-lit button on top of the burner. By pressing transparent
button on top of the burner for a short time only, the entire burner start, operation
and self-diagnosis control process is skipped. By pressing this transparent button
and holding it depressed for at least 3 seconds, the burner start and diagnosis
control process is commenced (the red light will flash fast). The Table below
explains some possible burner blockage cases, depending on error occurrence in
the burner start and self-diagnostics procedure. This information is available by
counting the number of flashes of the red LED (always the red one). The diagnosis
function can be discontinued by pressing the button on burner enclosure and
holding it depressed for at least 3 seconds.
Lamborghini burner error codes
and ways they are indicated
MACHINE STATUS INDICATOR
Condition
LED colour
Standby mode, other intermediary
modes
No light
Fuel heating in the burner starting
phase, waiting time max. 5 seconds
Yellow
Fuel / air mixture ignition stage
Yellow, flashing
Proper operation
Green
Improper operation, the infrared sen-
sor cannot see any flame
Green, flashing
Voltage drop
Yellow / red, flashing alternately
Burner blocked
Red
Error
Red, flashing
Scattered light on the sensor prior to
mixture ignition
Green / red, flashing alternately
Self-diagnostics
Red, quick flashing