Forssell Technologies MADA-2 Скачать руководство пользователя страница 3

not

 reset the converter digital circuitry nor does it change the sample rate back to power up defaults.  

Each time you power up the MADA-2, the “Over” LED will light up.  Press the reset  switch to turn-off 
the Over LED. 
 

External Sync Input: 

Your MADA-2 is supplied with an External Word Clock Sync function  External  Sync is selected by 
pressing the “Select” switch until the WC external sync LED is lighted.  If no valid WC is detected at 
the WC Input BNC connector, then the red SYNC LED will be lighted.  Once a valid WC is applied to 
the BNC connector, the red LED will turn off, indicating that the MADA is locked to the external WC.  
The MADA-2 should lock within one second of receiving a valid WC sync input signal. A wide range of 
WC input frequencies can be used, including vari-speed WC signals.  
 
The WC sync input level should be TTL compatible and needs to be terminated with a 75 ohm resistor.  
The MADA-2 WC input is a high impedance input. This allows several units to be feed sync input with 
from one single WC source.  To daisy-chain several units, you will need to use BNC Tee connectors  on 
each unit.  A 75 ohm terminator should be connected at the Tee connector of the very end of the chain.  
 

Analog Inputs: 

Analog inputs are provided on rear panel mounted XLR connectors.  The MADA-2 can accept either 
balanced or unbalanced input signals. 

Unbalanced signals result in a 6 dB lower headroom

. The XLR 

connectors are wired for pin #2 = + input, and pin #3 = - input signal polarities. The input impedance of 
analog inputs is approximately 3k ohm balanced.   
 

Level Calibration: 

Unless otherwise requested when your unit was ordered,  the MADA-2 is calibrated so that a  0 (775 
mv) dBu  analog input level produces –18 dBFs digital output level.  There are four sets of jumpers 
located on the MADA board inside the MADA-2 that will allow you to change the level calibration for 
the AD section. All four jumpers must be set for the same level calibration. 
 

Digital Outputs: 

There are two digital outputs available with the MADA-2.  One is an AES/EBU (AES3) 110 ohm digital 
output on a rear mounted XLR connector. The other is a 75 ohm SPDIF digital output on a rear mounted 
RCA connector. These digital outputs are isolated from each other and they may be used 
simultaneously.    
 
 

Digital to Analog  (DAC) Section Description: 

 

The DAC section MADA-2 is designed for the most demanding applications, where capturing musical 
performances with accuracy and honesty is required.  The MADA-2 accepts digital inputs with sample 
rates from 44.1k to 192k Fs.  The MADA-2 has AES3 (AES/EBU) 110 ohm on an XLR connector and 
SPDIF  75 ohm  RCA inputs.  Input selection is via a front panel push button switch with LED 
indicators showing which input is selected.   Other front panel LED indicators show input fault 
condition and SCR lock status. 

 
 
 
Level Calibration: 

Unless otherwise requested when your unit was ordered,  the MADA-2 is calibrated so that a  -18 dBFS  
digital input level produces a  0 dBu (775 mV) analog output level. There are two trim pots located on 

Содержание MADA-2

Страница 1: ...F t Forssell Technologies Inc MADA 2 2 Channel Analog to Digital and Digital to Analog Converter User Manual 72311 ...

Страница 2: ...DA 2 digital output word length is fixed at 24 bits The MADA 2 uses a 32 bit asynchronous decimation filter to provide various standard output sample rates from 44 1K to 192k The actual low jitter sampling clock that controls the AD converter chip timing is permanently set to sample at 196 3 kFs regardless of output sampling rate selection This process is called Asynchronous Sample Rate Conversion...

Страница 3: ...connectors are wired for pin 2 input and pin 3 input signal polarities The input impedance of analog inputs is approximately 3k ohm balanced Level Calibration Unless otherwise requested when your unit was ordered the MADA 2 is calibrated so that a 0 775 mv dBu analog input level produces 18 dBFs digital output level There are four sets of jumpers located on the MADA board inside the MADA 2 that wi...

Страница 4: ...ke the signal between pin 2 hot and pin 3 cold of the input XLR Pin 1 can be connected to either of these pins if desired Connecting pin 1 to pin 2 will produce an output signal that is out of phase so normally pin 1 is connected to pin 3 for single ended loads Pin 1 can be left floating too MADA 2 Specifications ADC specifications Sample Rates available 44 1k 48k 88 2k 96k 176 4k and 192k Level C...

Страница 5: ... 1Khz 18 dBu input output 0 dBFS IMD SMPTE 0 002 with 0 dBu input output 18 dBFs IMD SMPTE 0 05 with 18 dBu input output 0 dBFs General Specifications Power consumption 14 watts 120 VAC AC Line Voltage range 110 to 125 VAC and 220 to 250 VAC 50 or 60 Hz AC Line Voltage The MADA come preset for either 115 VAC or 230 VAC 50 60 Hz operation as indicted by a rear panel label The line voltage is select...

Страница 6: ... 18k 20k 22k 24k 26k 28k 30k Hz DA FFT linear scale of 2 KHz signal at 0 dBu output level with a 600 load Red Ch1 Blue Ch2 D A FFT HiRes Stereo at2c 140 0 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B u 20 30k 50 100 200 500 1k 2k 5k 10k 20k Hz DA FFT log scale 2 KHz signal at 0 dBu output level with a 600 load Red Ch1 Blue Ch2 ...

Страница 7: ...8k 20k 22k 24k 26k 28k 30k Hz DA FFT linear scale 2 KHz signal at 100 dBu output level Red Ch1 Blue Ch2 D A FFT HiRes Stereo at2c 140 0 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B u 20 30k 50 100 200 500 1k 2k 5k 10k 20k Hz DA FFT log scale of 2 KHz signal at 100 dBu output level with a 600 load Red Ch1 Blue Ch2 ...

Страница 8: ...16k 18k 20k 22k 24k 26k 28k 30k Hz DA FFT linear scale of Dual Freq 19 and 19 5 KHz signal at 0 dBu Output Level D A FFT HiRes Stereo dual freq at2c 140 0 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B u 20 30k 50 100 200 500 1k 2k 5k 10k 20k Hz DA FFT log scale of Dual Freq 19 and 19 5 KHz signal at 0 dBu Output Level ...

Страница 9: ...100 200 500 1k 2k 5k 10k 20k Hz DA Frequency Response at 96 KHz sample Rate D_A Jitter Spectrum 0 at27 160 0 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 d B r A 20 20k 50 100 200 500 1k 2k 5k 10k Hz DA Jitter FFT 44 1k Fs with 1 KHz 0 dBFs sine wave signal and 500 Hz sine wave jitter at 1 UI 177 ns amplitude ...

Страница 10: ...10 d B u 130 0 120 110 100 90 80 70 60 50 40 30 20 10 dBFS Deviation from Linearity Right scale with 0 dBFs to 130 dBFs Input ADC Measurements A D FFT at2c 160 20 155 150 145 140 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 d B F S 1k 22k 2k 3k 4k 5k 6k 7k 8k 9k 10k 11k 12k 13k 14k 15k 16k 17k 18k 19k 20k 21k Hz AD FFT linear scale with 0 dBu 5 KHz input 18 dBFs dig...

Страница 11: ... AD FFT log scale with 0 dBu 5 KHz input 18 dBFs digital output A D FFT Dual Freq at2c 160 20 155 150 145 140 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 d B F S 2 5k 47 5k 5k 7 5k 10k 12 5k 15k 17 5k 20k 22 5k 25k 27 5k 30k 32 5k 35k 37 5k 40k 42 5k 45k Hz AD FFT linear scale with dual frequency 19 and 19 5 KHz 0 dBu signal ...

Страница 12: ...k 50 100 200 500 1k 2k 5k 10k 20k Hz AD FFT log scale with dual frequency 19 and 19 5 KHz 0 dBu signal A D FREQ RESP at2c 3 1 2 8 2 6 2 4 2 2 2 1 8 1 6 1 4 1 2 1 0 8 0 6 0 4 0 2 0 0 2 0 4 0 6 0 8 d B r 1 20 40k 50 100 200 500 1k 2k 5k 10k 20k Hz AD High Frequency Response at 44 1k 48k 88 2k and 96k 96k is the limit of the test equipment ...

Страница 13: ...uency Freq Resp A D LINEARITY2 at2c 3 3 2 8 2 6 2 4 2 2 2 1 8 1 6 1 4 1 2 1 0 8 0 6 0 4 0 2 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 1 8 2 2 2 2 4 2 6 2 8 d B F S 130 0 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B F S 110 10 100 90 80 70 60 50 40 30 20 10 0 dBu Deviation from Linearity Right scale from 0 dBFs to 130 dBFs Output ...

Страница 14: ...0 200 500 1k 2k 5k 10k 20k 50k Hz T MADA 2 Freq Resp at 44 1k 48k 88 2k 96k 176 2k 196k Sample Rates Mic Pre FFT at2c 140 0 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B u 2k 32k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k 24k 26k 28k 30k Hz Analog to Analog FFT linear scale 96k Sample Rate 0 dBu Input Output ...

Страница 15: ...2k 5k 10k 20k Hz Analog to Analog FFT log scale 96k Sample Rate 0 dBu Input Output 18 dBFs Mic Pre FFT at2c 140 0 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B u 2k 32k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k 24k 26k 28k 30k Hz Analog to Analog FFT linear scale 96k Sample Rate 18 dBu Input Output 0 dBFs ...

Страница 16: ... 24k 26k 28k 30k Hz Analog to Analog FFT linear scale 96k Sample Rate 100 dBu Input Output 118 dBFs A A FFT Dual Tone at2c 140 0 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B u 2k 32k 4k 6k 8k 10k 12k 14k 16k 18k 20k 22k 24k 26k 28k 30k Hz A A FFT linear scale with dual frequency 19 and 19 5 KHz 0 dBu output signal ...

Страница 17: ...B u 10 30k 20 50 100 200 500 1k 2k 5k 10k 20k Hz A A FFT linear scale with dual frequency 19 and 19 5 KHz 0 dBu output signal Freq Resp Lo at2c 3 1 2 8 2 6 2 4 2 2 2 1 8 1 6 1 4 1 2 1 0 8 0 6 0 4 0 2 0 0 2 0 4 0 6 0 8 d B u 20 60k 50 100 200 500 1k 2k 5k 10k 20k Hz A A Frequency Response showing 3 dB response at 96k Fs ...

Страница 18: ...Freq Resp Lo at2c 90 0 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 d B u 20 60k 50 100 200 500 1k 2k 5k 10k 20k Hz A A Frequency Response showing full response at 96k Fs ...

Страница 19: ... 9k 10k Hz Jitter signal extracted from the WC output of MADC 2 measured with swept bandpass filter Blue trace is using internal oscillator Red is synced to WC input Spot Jitter for internal oscillator is 40 ps pk pk 20 ps peak or 14 ps rms maximum Spot Jitter of external WC sync is 130 ps pk pk 65 ps peak or 46 ps rms maximum 50u 1m 100u 150u 200u 250u 300u 350u 400u 450u 500u 550u 600u 650u 700u...

Страница 20: ... 1 6m 1 7m 1 8m 1 9m 2m 2 1m 2 2m 2 3m 2 4m 2 5m 2 6m 2 7m 2 8m 2 9m V 20 20k 50 100 200 500 1k 2k 5k 10k Hz FFT log scale of extracted jitter signal Red internal osc Blue external sync Note due to measurement technique jitter figures below 1 KHz may not be entirely accurate ...