8
If local codes permit grounding through the electrical supply neutral, connect both
the white neutral wire and the green ground wire from the oven to the white neutral
electrical supply wire.
•
&KHFNZLWKDTXDOLnjHGHOHFWULFDOLQVWDOOHULI\RXDUHQRWVXUHWKHRYHQLVSURSHUO\
grounded.
•
Single Oven - When a 4-wire, single phase 120/240 volt, 60 Hz., AC only
electrical supply is available, a 25-amp maximum circuit protection is required
RULIVSHFLnjHGRQWKHPRGHOVHULDOUDWLQJSODWHZKHQDZLUHVLQJOHSKDVH
120/208 volt 60 Hz., AC only electrical supply is available, a 20-amp maximum
circuit protection is required).
•
Double Oven - When a 4-wire, single phase 120/240 volt, 60 Hz., AC only
electrical supply is available, a 40-amp maximum circuit protection is required
RULIVSHFLnjHGRQWKHPRGHOVHULDOUDWLQJSODWHZKHQDZLUHVLQJOHSKDVH
120/208 volt 60 Hz., AC only electrical supply is available, a 35-amp maximum
circuit protection is required).
INSTALLATION INSTRUCTIONS
IMPORTANT: This appliance shall be installed only by authorized persons and
LQDFFRUGDQFHZLWKWKHPDQXIDFWXUHUšVLQVWDOODWLRQLQVWUXFWLRQVORFDOJDVnjWWLQJ
regulations, municipal building codes, electrical wiring regulations, local water
supply regulations.
STEP 1 - UNPACK THE OVEN
WARNING
Excessive Weight Hazard
Use two or more people to move and install oven.
Failure to do so can result in back or other injury.
1. Using two or more people, remove the oven and set it on cardboard to avoid
ǍRRUGDPDJH
NOTE: Do not use the handle or any portion of the front frame for lifting.
2. Remove the shipping materials and tape from the oven.
3. Remove the hardware package from inside the bag containing literature.
4. Remove and set aside racks and other parts from inside the oven.
5. Move the oven on the cardboard near where it will be installed.