Formula Sound AVC2 Скачать руководство пользователя страница 6

AVC2   SPECIFICATIONS

Frequency response

20Hz  -  30kHz

+/- 0.5dB

Distortion

O/P level             Attenuation

(THD and noise)  freq 1kHz

0dBu

     0dB

< 0.01%

0dBu

     12dB

< 0.015%

0dBu

     30dB

< 0.05%

Noise measured  20Hz-20kHz

Equiv. input noise      < -90dBu

INPUTS

Electronically balanced, connect pins 1 & 3 to screen pin 2 hot for unbalanced use

XLR Connector

Pin 1 screen  Pin 3 -Ve Non Phase   Pin 2 +Ve Phase

Input impedance

Balanced     20K ohms
Unbalanced   10K ohms

Maximum input level

+22dBu

Clip indicator

Indicates @   +20dBu

OUTPUTS   Electronically balanced, connect pins 1 & 3 to screen pin 2 hot for unbalanced use
XLR Connector

Pin 1 screen  Pin 3 -Ve Non Phase   Pin 2 +Ve Phase

Source impedance

100 ohms

Minimum load impedance

600 ohms

Operating Threshold Range

High range

Average level

adjustable  +5 dBu   -2dBu

Low range

Average level

adjustable  -8 dBu   -14dBu

N.B. If a signal generator is used as the source for making adjustments to the operating threshold, the threshold will
be approx. 6dB lower than using a music source due to the averaging measurement which the unit uses for control.
For operation outside the above ranges contact Formula Sound Ltd.

ATTENUATOR RANGE               -3dB  -6dB  -9dB  -12dB  -15dB  -18dB  -24dB  -30dB

CONTROL CHAIN
A control chain with a flat frequency response  Linear,  “A” weighted, or a combination of both may be selected to
control the attenuators.

AUX CONNECTIONS          1 & 2 Mute   3 & 4 Dim output -20dB   5 & 6 Remote warning   7 & 8 Level 2 select

POWER
220-240V AC (110V to order)     Mains Fuse 250mA slow blow     I.E.C.  Mains connector

FINISH
Front and Rear panels - Black anodised aluminium with silver notation
Case black plastic-coated steel.

DIMENSIONS
19" Rack mounting  1RU
Width 482mm (19")  Depth 200mm (7.9")  Height 44mm  (1.75")

FORMULA SOUND LTD.
Ashton Road
Bredbury
Stockport
Cheshire
UK
SK6 - 2SR           TEL 0161 494 5650  (+44 161 494 5650)    FAX 0161 494 5651  (+44 161 494 5651)

Formula Sound reserve the right to alter specifications at any time without notice.

Содержание AVC2

Страница 1: ...AVC2 AUTOMATIC VOLUME CONTROL USERS MANUAL XLR VERSION ...

Страница 2: ... clip indicator is provided to show when the input stage of the AVC2 is being over driven Reducing the input level will gently release the attenuation pro vided by the AVC2 The AVC2 has no external controls for the operator to worry about just a bargraph meter and some indicator led s to inform the operator of the status of the unit An external remote warning indicator may be connected to warn the...

Страница 3: ...arth connection is only connected to the case and this must always be connected to MAINS EARTH As supplied the unit will be detecting the incoming signal to control the output level AUXILIARY CONNECTIONS 2 X 4 way connectors are provided for the auxiliary connections The connectors are labelled 1 2 3 4 for the first connector and 5 6 7 8 for the second connector The mating halves for these connect...

Страница 4: ...later section INTERNAL ADJUSTMENTS The AVC2 is slow acting to differentiate between dynamic peaks of music and an increase in aver age level Bear this in mind when making adjustments INTERNAL ADJUSTMENTS Do not attempt to make any internal adjustments unless you are qualified to do so and you know what you are doing ALWAYS DISCONNECT POWER BEFORE REMOVING COVERS Access is gained by removing the to...

Страница 5: ......

Страница 6: ...as the source for making adjustments to the operating threshold the threshold will be approx 6dB lower than using a music source due to the averaging measurement which the unit uses for control For operation outside the above ranges contact Formula Sound Ltd ATTENUATOR RANGE 3dB 6dB 9dB 12dB 15dB 18dB 24dB 30dB CONTROL CHAIN A control chain with a flat frequency response Linear A weighted or a com...

Отзывы: