background image

For line level input 

press the “LINE” switch on the back panel for the required channel (Line LED 

on the front panel will also light). 
 
Set the front panel volume control to 3/4 clockwise position. Connect the line level source and 
adjust the gain control on the back panel (adjacent to the input XLR) until the LED level meter 
reads 0dB. 
 
Selecting “Mute” on the front panel will mute the audio on that channel.  
 
Selecting “LF Filter” on the front panel will introduce an LF Filter into the signal path, the LF filter 
rolls off at up to 24dB/octave. 
 
 The LED meter indicates output level, the clip LED will come on if the output goes above 
+18dB. 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Formula Sound Limited 
Unit 23; Stadium Business Centre 
North End Road 
Wembley 
HA9 0AT 
 
Tel +44 (0) 208 900 0947         Fax +44 (0) 208 903 8657 

Email [email protected] 

 
www.formula-sound.co.uk 
 
 
 
 
 
 
 
 
 
 
 
 