Length/Width
Depth
APTOS
™
PEDESTRIAN
SURFACE MOUNT INSTALLATION & WIRING INSTRUCTIONS
page 1 of 5 | 12-08-20
© 2020 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
TOOLS NEEDED
MATERIALS INCLUDED
STEP BY STEP
Prepare the incoming power
• Before pouring concrete footer, run
properly sized conduit and cabling to
each fixture location according to local
code requirements. Refer to figure
above for dimensions for conduit entry
envelope size and location on fixture.
Forms+Surfaces is not responsible
for site preparation and footings.
Note: Conduit should not protrude more
than 2" above mounting surface.
Pour concrete footer
• Mix and pour concrete footer according
to concrete manufacturer’s instructions.
• A sufficient footer size depends on
frost and other considerations to be
determined by the installer. (A minimum
of a 20" square x 45" deep footer is
recommended.)
Insert J-bolt anchors
• Insert 3/4"-10 x 24" galvanized steel
J-bolt anchors (a) into concrete.
• Use template (included) to position J-bolt
anchors in proper locations. Tops of J-bolt
anchors must be a minimum of 1-3/4"
above concrete surface.
• Allow concrete to set completely, in
accordance with concrete manufacturer’s
instructions, before moving to step 4.
FOR ALL APTOS PEDESTRIAN LIGHTING
1/8" and 5/32"
security hex bit
Template
(upon request)
Loctite
a
ratchet
1-1/8
"
socket
1/8" hex bit
5/16" hex bit
wire strippers
c
f
e
b
g
h
d
Ø .88
Ø 7.50
Ø 4.01
Ø 1.88
Ø 12.50
2.95
a a
1 3/4"
Minimum
door side