INSTALLATION INFORMATION

 

 

CONDITIONS OF INSTALLATION

 

 

It is the law that all gas appliances are installed only by a competent (e.g. 
Registered) Installer, in accordance with the installation instructions and the Gas 
Safety (Installation and Use) Regulations 1998.  Failure to install appliances 
correctly could lead to prosecution.  It is in your own interest and that of safety to 
comply with the law. 

 

The fire may be fitted below a combustible shelf provided that the shelf is at least 
200mm above the top of the appliance and the depth of the shelf does not exceed 
150mm. 

 

The fire may be installed below combustible shelves which exceed 150mm deep 
providing that the clearance above the fire is increased by 15mm for each 25mm 
of additional overhang in excess of 150mm. 

 

No purpose made additional ventilation is normally required for this 
appliance when installed in G.B.  When installed I.E. please consult 
document I.S. 813 : 1996 Domestic Gas Installation which is issued by the 
National Standards Authority of Ireland.  Any purpose made ventilation 
should be checked periodically to ensure that it is free from obstruction.

 

 

If the chimney or flue has been previously used by appliances burning fuels other 
than gas they must be swept prior to the installation of this fire. 

 

If this appliance is fitted directly on to a wall without the use of a fireplace or sur- 
round, soft wall coverings such as wallpaper, blown vinyl etc. could be affected by 
the heat and hot convection air and may discolour or scorch.  This should be con- 
sidered when installing or decorating. 

 

The Model number of this appliance is as stated on the rating plate affixed to the 
control panel of the fire and the appliance is manufactured by:- 

 

Formosa Fires

Содержание Rivas

Страница 1: ...ingthe applianceandretainedforfuturereference Model No s AICC MN2 AICC SN2 are only for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E Model No s AICC MP AICC SP are only for use on...

Страница 2: ...f 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is...

Страница 3: ...nce a year by a GAS SAFE registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which mu...

Страница 4: ...ikely event of a failure of the igniter the fire can be lit as follows Depress the control knob and turn anti clockwise to the position marked pilot Hold in the control knob for a few seconds to allow...

Страница 5: ...In the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if necessary replace with a AA size alkaline battery It is impor tant that only an alkaline batter...

Страница 6: ...nsure that the fire has been allowed to fully cool CLEANING THE TRIMS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be cho...

Страница 7: ...elbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See figure 1 below Fig 1 b Position the two halves...

Страница 8: ...amic rail as a guide for placement See figure 3 below Fig 3 Square Random Square Random Square d Select two of the large square coals two of the large random coals and arrange behind the front row of...

Страница 9: ...d row of coals using the ribs in the fuelbed matrix as a guide for placement See figure 5 below Fig 5 Random Square Random Square Random f Select the remaining two large square coals and two random co...

Страница 10: ...rly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when hand...

Страница 11: ...uch as a GAS SAFE registered gas installer The part numbers of the user replaceable parts are as follows these are available from Formosa Fires who may be contacted at the address shown below Fuelbed...

Отзывы: