Formax AutoSeal FD 2052 Скачать руководство пользователя страница 4

LOWER FOLD TABLE

UPPER FOLD TABLE

5.  Install the lower fold table and plug the cord (figure 2a) into the fold plate receptacle.

6.  Install the upper fold table and plug the cord (figure 2b) into the fold plate receptacle.

7.  Plug machine into wall outlet.

CAUTION:

 Do not operate the machine without the fold tables plugged in. 

NOTE:

 The display screen should read (COUNT: 0000) and a fold setting (i.e. Letter, ZigZag, Single or 

custom #) when the machine is plugged in and the power is turned on.

Start/Stop...................Starts and stops the machine

Test.............................Allows one form to be folded

Counter Reset............Resets counter and resets faults

Display Screen...........Displays all current functions

Standard Folds Menu:

The Standard Folds Menu consists of three folds; Letter (C-fold), Zig-Zag (Z-fold), and Single (Half fold). By 

pressing the green button in the Standard Folds Menu, you can toggle between the fold settings. An indicator 

will light up on the fold type selected. These fold types are standard for 11” and 14” forms. The 2052 will 

identify the form length 11” or 14” via a sensor.

Custom Folds Menu:

To use a custom fold setting press one of the custom fold buttons (1, 2, 3-9). Press the 3-9 button multiple 

times to toggle through the 3

rd

 and the 9

th

 custom folds.

CONTROLS

2

 Figure 2b

 Figure 2a

Содержание AutoSeal FD 2052

Страница 1: ...FD 2052 AutoSeal OPERATOR MANUAL FOURTH EDITION 12 2007...

Страница 2: ...1 UNPACKING AND SET UP 1 2 CONTROLS 2 OPERATION 3 CUSTOM FOLDS 3 4 Measuring Fold Lengths 3 Custom Fold programming 4 BATCH COUNTING 4 5 DAILY MAINTENANCE 5 TROUBLESHOOTING 6 7 DETERMINING FOLD TYPE 8...

Страница 3: ...ms Weight 90 lbs Power supply FD Model 120 volts 60 Hz 3 5 amps FE Model 240 volts 50 Hz 3 5 amps UNPACKING AND SETUP 1 Check package for shipping damage If there is shipping damage do not discard the...

Страница 4: ...st Allows one form to be folded Counter Reset Resets counter and resets faults Display Screen Displays all current functions Standard Folds Menu The Standard Folds Menu consists of three folds Letter...

Страница 5: ...ired setting SETTING CUSTOM FOLDS Example 1 Uneven Z a Measure the length of panel A B b Measure the length of panel B c Enter these measurements according to the instructions on next page Example 2 U...

Страница 6: ...nter the manual batch counting mode press the Batch Count button and select MANUBATCH by pressing the button Fig 3a 2 Select the number of sheets to be folded by pressing the or buttons Fig 3c then pr...

Страница 7: ...counting program selected will remain on after the job is processed You must press the Batch Counting button to turn off the light and cancel the batch count setting Sheets Number of sheets of paper i...

Страница 8: ...ng tool located under the top fold table apply the tool to the upper metal roller gure 4 and turn clockwise until the paper jam is clear Caution Do not apply excessive force or rollers may be damaged...

Страница 9: ...he photo eyes The rst set of lights on the left is used to adjust the photo eye sensitivity for the fault detection There are three lights to help you do this The rst is a red light low signal The sec...

Страница 10: ...8 DETERMINING FOLD TYPE Two Standard Folds 11 Z 11 C Refer to Operator Manual for custom fold setup 11 Z Fold 11 C Fold Leading glue edge Leading glue edge 11 Z Fold 11 C Fold Glue Glue Glue Glue...

Страница 11: ...leading edge of the pressure seal form 3 If the folds on this test sheet do not line up with the perforated folds on the form the fold plates need to be adjusted up or down to make the folds line up...

Страница 12: ...e conveyor 5 Install the conveyor mounting bolts gure 7 5 Attach the conveyor to the 2052 6 Install the stacker wheel assembly into the holes indicated below gure 8 7 Adjust the stacker wheels to conv...