Problem
Check
Solution
The register
can’t run.
Is there a
power supply
inside the
meter ?
Is the
operating
power too
low ?
Maybe there is
Check that the power supply
indicator ( L1, L2 & L3 LED )
is
burning.
If the operating power is too
low, the spacing interval of the
pulses will take some more
time, this is why it seems like
the register can’t run.
Please contact technical
support to replace this meter.
No pulse output.
Is DC power
supply connected
to the
meter ?
Is the
connection
correct ?
Maybe there is
a fault in the
Check the external voltage
source
(Ui) is 5-27V DC.
Check correct connection:
connect 5-27V DC to connector
20 (anode), and the signal wire
(S) to connector 21 (cathode).
Please contact technical
support to replace this meter.
Pulse output
rate wrong.
Maybe there is
a fault in the
inside
circuit.
Please contact technical
support to replace this meter.