background image

 

 

FORK MEASURING COMPANY 

Vavdi Sr.No. 17, Plot No 55B, Rani Industrial Estate 

Gondal Road, Rajkot-360002 

 

INSTRUCTION MANUAL FOR DIGITAL INDICATOR (302-012) 

 

 

Tolerance setting “TOL” 

a)

 

Under “ SET-TOL” mode , press button 

MODE

 to set lower tol. 

While “      ” icon is blinking. And the last digit is blinking now, then press button 

MODE

 to modify 

the number from 0-9. Then press button 

ZERO/ON/OFF

 to blink the left digit , the set the 

intended value as above process till finishing all digits.

 

 

b)

 

Press button 

SET

 again to move to upper tol. Setting, while 

“       ”icon is blinking, set the intended value as same procedure as 
lower tol. Setting . 

 

 

Presetting value “CAL” 

a)

 

Under “SET-CAL” mode, press button to set the present 

MODE

 value. The last digit is blinking and 

can be modified from 0 to 9 by pressing button 

MODE

 . 

b)

 

Press button 

ZERO/ON/OFF 

to blink the left digit, finish the setting for all other digits per same 

procedure. 

c)

 

Press button to 

SET

 quit. The setting can be applied to both metric and inch mode. 

d)

 

If L –press button 

ZERO/ON/OFF

, the preset value goes back to zero and preset mode is quitted. 

 

 

Changing between metric / inch system “mm-in

 

a)

 

Under “SET-mm-in” mode , press button 

MODE

 to change metric/ inch system. “mm” is blinking 

on metric system , and “in” is blinking on inch system. 

b)

 

Press button 

SET

 to quit. 

 

 

Measuring Direction Setting “dir” 

 

a)

 

Under “SET-dir” mode , press button 

MODE

 to change the measuring directly. Sign “

+

” stands for 

normal direction . sign “

-

”stands for reverse direction. “        “displayed on reverse direction. 

b)

 

Press button 

SET

 to quit 

 

 

 

Содержание 301-012

Страница 1: ...LCD 8 MODE button 9 SET button 10 ZERO ON OFF button Features Ip56 protection level Absolute and relative measurement Metric and Inch conversion Origin data set tolerance set Measuring direction change with data output Automatic power off Stem Ø8mm as standard Temperature 10º 60º Working temperature 0 40º Technical Specification Code Range Reading Accuracy 302 012 0 12mm 0 0 5 0 001mm 0 00005 0 00...

Страница 2: ... c Long press ZERO ON OFF button for power OFF Zero setting a Upon ABS mode press ZERO ON OFF Button for zero or preset value b It goes to zero when switching from ABS to INC mode c No zero setting at INC mode Switching mode between ABS and INC press button SET to change mode between ABS INC ABS displayed at ABS mode but no mode displayed at INC mode Replacing battery In case of below situations p...

Страница 3: ...ing and tracing Max and Min value a Icon MAX is displayed on this mode Now the Max value will be memorized b Press button SET then MIN is displayed now Min value will be memorized c Press button SET then MAX MIN is displayed it shows the margin between Max and Min value d If pressing button ZERO ON OFF the memorized Max and Min value can be removed e No ABS INC switching on Max Min mode f No ABS I...

Страница 4: ...ress button to set the present MODE value The last digit is blinking and can be modified from 0 to 9 by pressing button MODE b Press button ZERO ON OFF to blink the left digit finish the setting for all other digits per same procedure c Press button to SET quit The setting can be applied to both metric and inch mode d If L press button ZERO ON OFF the preset value goes back to zero and preset mode...

Отзывы: