Make sure the unit is disconnected from power mains before removing the protection. Maintenance of the ventilator means regular
cleaning of the ventilator surfaces of dust and cleaning and replacement of the filters. To access the basic assembly units follow the steps:
Turn off the ventilator using the remote control or the buttons on the indoor unit. Then turn the power completely off.
1. Press the latches on the side of the indoor control unit to take off the front part.
Please make sure the thermal actuator rod is in lower position during re-installation of the front panel. If the thermal actuator
rod is up, please wait for about 2 minutes until it goes down.
WARNING!
Do not put on the front panel
until the thermal actuator rod
is completely lowered.
Blinking of the white LED
indicates that the
THERMAL ACTUATOR IS NOT LOWERED
2. Disconnect the connector from the control board. While removing the connector do not pull the cable. Uplift it with a flat screw driver
of a respective size.
Remove the connector from the
control board
3. Remove the sound-absorbing material, fan unit, and the regenerator unit from the air duct.
DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE
OPERATIONS!
MAKE SURE THE UNIT IS DISCONNECTED FROM POWER MAINS BEFORE REMOVING
THE PROTECTION
TECHNICAL MAINTENANCE