foris TwinFresh Expert RW1-50 Скачать руководство пользователя страница 1

TwinFresh Expert RW1-50 V.3

Single-room reversible energy recovery ventilator

USER’S MANUAL

Содержание TwinFresh Expert RW1-50

Страница 1: ...TwinFreshExpertRW1 50V 3 Single room reversible energy recovery ventilator USER S MANUAL...

Страница 2: ...as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit Disconnect the uni...

Страница 3: ...sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children s...

Страница 4: ...s operation Name Number Indoor assembly unit of the ventilator 1 pc Air duct 1 pc Sound absorbing material 1 pc Fan assembly 1 pc Heat exchanger assembly 1 pc Outer ventilation hood 1 pc Remote contro...

Страница 5: ...class II electric appliance Ingress protection rating against access to hazardous parts and water ingress is IP24 The ventilator design is constantly being improved thus some models may be slightly di...

Страница 6: ...an unit Creates air flow Regenerator unit Provides heat recovery Sound absorbing material A layer of sound absorbing material for attenuation of noise generated during the ventilator operation The ven...

Страница 7: ...ithout changing the operation mode Regeneration the ventilator runs in two cycles 70 seconds each with heat and humidity regeneration Cycle I Warm stale air is extracted from the room and flows throug...

Страница 8: ...a mounting foam Mounting wedge Install the air duct with the minimum slope of 3 mm downwards from the outer wall side The air duct can be cut by calculating preliminary the required length or after f...

Страница 9: ...s 5 Unlatch and detach the front part of the indoor unit from its back part WARNING Do not put on the front panel until the thermal actuator rod is completely lowered Blinking of the white LED indicat...

Страница 10: ...ct the socket connector to the control board If the wall thickness is less than that in the layout of the blocks inside the wall from the Technical Data section you can unfasten the fine filter holder...

Страница 11: ...elay sensor Power supply AC 100 240 V 50 60 Hz ON DIP 1 2 3 4 DIP switch and USB connector under the cover EXTERNAL CONNECTIONS DIAGRAM VENTILATOR SETUP Prior to operating the ventilator set it up usi...

Страница 12: ...et speed Party mode Activation of Speed III by timer 4 hours by default Night mode Activation of Speed I by timer 8 hours by default DIP SWITCH POSITIONS Ventilator network setup 1 OFF master unit her...

Страница 13: ...n unit in the air supply mode This mode may be activated only via the mobile application Filter 90 days after installation of the cartridge the filter replacement indicator starts glowing In this case...

Страница 14: ...erates in the supply or extraction mode at a set speed The fan rotation direction depends on the position of the DIP switch No 3 Timer control buttons Party mode the timer activates operation of the u...

Страница 15: ...ile device to a Wi Fi access point FAN 16 characters of the ID number indicated on the control board of the ventilator Wi Fi access point password 11111111 1 2 4 5 6 8 7 3 Enter the Vents TwinFresh V...

Страница 16: ...OF MOBILE APPLICATION INDICATORS Current type of connection to the ventilator Home connection or connection via a cloud server through Internet respectively Speed III activation indicator It goes on...

Страница 17: ...ate SENSOR SETUP To set up sensor operation via the mobile app go to Menu Settings Sensors Humiditysensor activation of the humidity sensor When the indoor humidity exceeds the set point the unit swit...

Страница 18: ...operation The need to replace the filters is signalled by the indicator in the upper section of the CONTROL menu Replace the filter and reset the filter timer To reset the filter timer via the mobile...

Страница 19: ...tor Wi Fi parameters via the mobile app go to Menu Connection Wi Fi Setup Press the Receive button to display the current Wi Fi settings Select one of the Wi Fi operation modes Access Point access poi...

Страница 20: ...nt of the Wi Fi router In this case the Master unit can operate with the number N of Slave units limited by the technical characteristics of the router Master Slave No 1 Slave No N Mobile device Mobil...

Страница 21: ...ntrol board To replace the battery power off the ventilator remove the front panel and the cover protecting the control board Remove the battery and install the new one Battery type CR1220 CONNECTING...

Страница 22: ...Internet connection provided by the home server may result in temporary loss of communication with the ventilator To manage the master ventilator create a new account Open the mobile app and go to Me...

Страница 23: ...unit functionality is not changed To open the air duct pull the front panel while holding the special recesses The fan starts operating according to the actual speed setting Air duct shut off Air duc...

Страница 24: ...on during re installation of the front panel If the thermal actuator rod is up please wait for about 2 minutes until it goes down WARNING Do not put on the front panel until the thermal actuator rod i...

Страница 25: ...ust may accumulate on the heat exchanger block even in case of regular maintenance of the filters Clean the regenerator regularly to ensure its high heat recovery efficiency Vacuum clean the regenerat...

Страница 26: ...sportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours POSSIBLE REASONS AND TROUBLESHOOTING Problem Possible reasons Troubleshooting When switching on...

Страница 27: ...ller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including...

Страница 28: ...28 TwinFresh Expert RW1 50 V 3...

Страница 29: ...29 TwinFresh Expert RW1 50 V 3...

Страница 30: ...30 TwinFresh Expert RW1 50 V 3...

Страница 31: ...TE The unit _____________________________________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Страница 32: ...Foris241EN_A4_stkr 01...

Отзывы: