Forgeon Bolt 650 Скачать руководство пользователя страница 3

EN

Safety and Protection

WARNING: This unit unit has no user-serviceable parts inside. Opening the casing 
presents a risk of electrocution and will void the product’s warranty. Forgeon will not be 
responsible for any result of improper use, including but not limited to, any use of the 
product outside of its intended purpose or use inconsistent with the warranty terms 
available online. (Warranty information is available at https://forgeon.es/garantia and this 
manual is avaliable at  https://forgeon.es/bolt/bolt_manual.pdf

Short-circuit protection (SCP) 

Over current protection (OCP)

Over-voltage protection (OVP) 

Over Power Protection (OPP)

Under Voltage Protection (UVP)

Over temperature protection (OTP)

Over-voltage protection for the 12V, 5V and 3.3V DC 
outputs is required to comply with the ATX specification. 
OVP shuts down the PSU in the event that the DC outputs 
exceed a set level, determined by the PSU manufacturer. 
The minimum voltage levels required for compliance are 
13.4V for the +12V rail(s), 5.74V for the +5V rail and 3.76V 
for the 3.3V rail.

The over-power protection (OPP) kicks in when the 
power we pull from a PSU exceeds its maximum rated 
capacity. Usually, the manufacturers give a little room for 
overpowering the PSU, so the OPP threshold is set to 50 to 
100W (in some cases even more) above the maximum rated 
wattage of the PSU. In 12V rail PSUs, where OCP 
is meaningless in most cases, OPP takes over its role and 
shuts down the PSU in case the +12V rail is overloaded.

A short-circuit is defined as any output impedance of less 
than 0.1 ohms. Amongst other things, SCP ensures that the 
PSU shuts down should the 3.3V, 5V and 12V rails short to 
any other rail, or to ground. It also ensures that no damage 
should occur to the unit, or your PC’s components in the 
event of a short.

is an electronic overload protection circuit that is often 
specified in data sheets as OCP (= Overcurrent Protection) 
.The power supply as well as the connected loads are 
electronically protected against overload by limiting the output 
current to a maximum value. OCP is a feature that uses one or 
more circuits to prevent a power supply from delivering more 
current than its circuits and cables can handle.

Under-voltage protection for the 12V, 5V and 3.3V DC 
outputs. UVP shuts down the PSU in the event that the 
DC outputs exceed a set level, determined by the PSU 
manufacturer. 

Continuous high temperatures are undesirable and can 
lead to malfunctioning or more damage to the supply, 
connected circuits or downstream equipment. The over 
temperature protection (OTP) therefore ensures that the 
supply operates within the safe design temperature and 
shuts the supply down whenever this is exceeded.

Содержание Bolt 650

Страница 1: ...Bol t INSTRUCTIONS MANUAL MANUAL DE INSTRUCCIONES...

Страница 2: ...gh quality Japanese capacitors a 140mm fan with silent PWM capability to keep all components well cooled and a unique design Bolt comes with all standard protections OVP SPC UVP OPP OCP OTP for the sa...

Страница 3: ...shold is set to 50 to 100W in some cases even more above the maximum rated wattage of the PSU In single 12V rail PSUs where OCP is meaningless in most cases OPP takes over its role and shuts down the...

Страница 4: ...550mm1 50mm 150mm 150mm1 50mm 150mm SATA IDE SATA 550mm MOLEX MOLEX MOLEX 150mm FDD AC INPUT AC100 240V 47 63HZ DC OUTPUT V5 3 3V 12VMBPH 12VCPU 12VVGA1 12VVGA2 12V 5VSB MAX OUTPUT 20A 20A 25A 25A 30A...

Страница 5: ...W 750W MAX POWER 750W Cable Listing Power table Power efficiency Bol t 750W MAIN BOARD CPU PCI E x1 20 4Pin 4 4 CPU 2 cables SATA 2 cables Floppy adapter 4 pin MOLEX x2 x3 x1 x9 600mm 700mm 550mm SATA...

Страница 6: ...W 850W MAX POWER 850W Cable Listing Power table Power efficiency Bol t 850W MAIN BOARD CPU PCI E x1 20 4Pin 4 4 CPU 2 cables SATA 2 cables Floppy adapter 4 pin MOLEX x2 x3 x1 x9 600mm 700mm 550mm SATA...

Страница 7: ...our wall outlet or UPS and from the existing power supply 2 Disconnect all the power cables from your video card motherboard and all other peripherals SATA MOLEX 3 Follow the directions in your chassi...

Страница 8: ...directly to your motherboard B If your motherboard has a 20 pin socket you must detach the four pin cable from the 24 pin connector and then plug the 20 pin cable onto your motherboard without connec...

Страница 9: ...ath 2 High voltages are present in the power supply Do not open the power supply case or attempt to repair the power supply there are no user serviceable components 3 This product is designed for indo...

Страница 10: ...a calidad un ventilador de 140mm con capacidad PWM silencioso para mantener todos los componentes bien refrigerados y un dise o nico Bolt incluye con todas las protecciones est ndar OVP SPC UVP OPP OC...

Страница 11: ...OPP se establece en 50 a 100W en algunos casos incluso m s por encima de la potencia nominal m xima de la fuente de alimentaci n En las fuentes de alimentaci n de un solo carril de 12V donde el OCP no...

Страница 12: ...DE SATA 550mm MOLEX MOLEX MOLEX 150mm FDD Potencia nominal AC AC100 240V 47 63HZ Corriente de salida DC V5 3 3V 12VMBPH 12VCPU 12VVGA1 12VVGA2 12V 5VSB Carga m xima 20A 20A 25A 25A 30A 30A 0 3A 2 5A C...

Страница 13: ...W 420W 420W 750W Potencia Total 750W Listado de cables y conexiones Tabla de alimentaci n Eficiencia de la fuente de alimentaci n Bol t 750W MAIN BOARD CPU PCI E x1 20 4Pin 4 4 CPU 2 cables SATA 2 cab...

Страница 14: ...W 480W 480W 850W Potencia Total 850W Listado de cables y conexiones Tabla de alimentaci n Eficiencia de la fuente de alimentaci n Bol t 850W MAIN BOARD CPU PCI E x1 20 4Pin 4 4 CPU 2 cables SATA 2 cab...

Страница 15: ...a de corriente y de la fuente de alimentaci n existente 2 Desconecte todos los cables de alimentaci n de su tarjeta de v deo placa base y todos los dem s perif ricos SATA y MOLEX 3 Siga las instruccio...

Страница 16: ...es de la fuente de alimentaci n directamente a su placa base B Si la placa base tiene una toma de 20 clavijas debe separar el cable de cuatro clavijas del conector de 24 clavijas y luego conectar el c...

Страница 17: ...limentaci n est n presentes altos voltajes No abra la carcasa de la fuente de alimentaci n ni intente reparar la fuente de alimentaci n pues carece de componentes que pueda reparar el usuario 3 Este p...

Страница 18: ...Bol t...

Отзывы: