background image

OWNER’S MANUAL

CANADIAN STANDARDS

MINI-SPLIT AIR CONDITIONER 

12,000 BTU (EER13)

Before using this air conditioner, please read the following instructions carefully and keep
this manual along with your proof of purchase in a safe place for future reference.

MODEL: 13-05022

00246-20/08/07

MODE

ON / OFF

© Copyright, Sunrise Tradex Corp., 2007

Содержание 13-05022

Страница 1: ...00 BTU EER13 Before using this air conditioner please read the following instructions carefully and keep this manual along with your proof of purchase in a safe place for future reference MODEL 13 050...

Страница 2: ...tes 11 Maintenance 12 13 Troubleshooting 14 15 Technical specifications 16 Warning 16 Installation setup diagram 17 Installation location 18 Installation instructions 19 24 Electrical wiring indoor un...

Страница 3: ...nds or spray water or other liquid inside the unit Do not place any foreign objects on the outdoor unit Make sure the air conditioner is well grounded according to local electricity codes and that the...

Страница 4: ...IAGRAM INDOOR UNIT Air in Panel Air filter Front case Air out Run Timer Louver Remote control Drain hose Air in Air out Air outlet grill Suction and liquid refrige rant piping Wiring cover Handling sw...

Страница 5: ...ontrol to the inside unit Do not drop or throw the remote control Do not leave the remote control in a location exposed to direct sunlight or near a heat source Do not spray any liquid or immerse the...

Страница 6: ...e or decrease the degrees by 1 When in COOL FAN or HEAT mode the temperature can be set from 16 C to 30 C 61 F to 86 F The temperature cannot be changed in AUTO or DEHUMIDIFYING mode ON OFF Press this...

Страница 7: ...unit fan will run 4 SETTING THE FAN SPEED Press on FAN and set the speed Each level is paired with a matching icon 5 OSCILLATION Press on SWING to start the automatic oscillation of the louvers Press...

Страница 8: ...ed and temperature cannot be changed 3 OSCILLATION Press on SWING to start the automatic oscillation of the louvers Press again to cancel 1 Press ON OFF to turn air conditioner on 2 SETTING TO DEHUMID...

Страница 9: ...simulateneously In AUTO mode the temperature will automatically be set to 25 C the temperature can not be changed It is recommended to stabilize the room humidity rate and temperature before using th...

Страница 10: ...t the desired time 0 5 to 24 h before the air conditioner turns off TIMER MODE ON OFF When the TIMER is on you can program the air conditioner to automatically turn on TIMER ON or shut off TIMER OFF a...

Страница 11: ...IFYING mode fan runs only at LOW speed it cannot be changed SLEEP MODE When the unit is COOLING or DEHUMIDIFYING if the SLEEP operation is on the set temperature will increase BY 1 C every hour until...

Страница 12: ...ust be properly grounded Do not connect the ground to gas or water pipes lightning rods lighting poles or telephone cable lines Do not leave animals or plants exposed directly to the coolling airflow...

Страница 13: ...use water above 45 C to prevent finish discoloration or plastic distortion 3 Push aside the holding brackets to reposition the panel Make sure the panel is correctly clipped For a maximum efficiency...

Страница 14: ...winter time please follow these instructions 1 Turn the air conditioner off and cut the circuit breaker off 2 Clean the filters and other parts as well as the outdoor and indoor unit enclosures 3 Bef...

Страница 15: ...ormation of plastic due to sudden change in temperature Is the remote control out of the appropriate working distance with the indoor unit Is there anything blocking the signal transmission between th...

Страница 16: ...ide wall Tradex Corp Tradex Corp www sunrisetradex com 1 800 686 2175 IMPORTANT NOTICE It is important to have your mini split air conditioner installed by a Sunrise Tradex Corp certified installer fo...

Страница 17: ...nter connecting conductors length should not exceed 11 m 444 875 Refrigerating pipe lenght must be limited between 4 10 m 157 484 393 75 If the length exceeds 7 62 m 300 the cooling capacity may becom...

Страница 18: ...nstalled by a Sunrise Tradex Corp certified installer for your warranty to be valid A mini split air conditioner installed by a technician other than a Sunrise Tradex Corp certified installer will voi...

Страница 19: ...ugh space to allow access for routine maintenance 8 Install in a location where is a least 1 m 39 3 8 from other electric appliances such as television audio device etc 9 Select location where is easy...

Страница 20: ...rmined refer to Fig 2 2 Insert the piping hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole INSTALL THE CONNECTION PIPES Connect th...

Страница 21: ...eration procedures 1 Open the surface panel 2 Open the cover and cover plate of electric box Right figure 3 Remove the receiving window as shown in the below left figure Cover of electric box Support...

Страница 22: ...board 5 way terminal board 8 way terminal board 3 way terminal board 6 way terminal board Power connection cord Power connection cord Cooling heating only type Cooling heating only type Cooling only...

Страница 23: ...rd Power connection cord Power connection cord Cooling heating only type Cooling only type Cooling heating only type Cooling only type Ground circuit of indoor unit Ground circuit of outdoor unit Grou...

Страница 24: ...e pipe should be fixed by the fixed nut and the wiring cover should be also fixed NOTE 1 The connecting wire and connection pipe should touch each other 2 Top cover of outdoor unit and electric box as...

Страница 25: ...s firm enough Shown in Fig 6 4 The height of the installed loca tion should be 2 m 78 3 4 or more from the floor Wrapping tape Connection pipes Power connection cord Fig 4 Drainage hose Right piping R...

Страница 26: ...0 bar 6 Dismantle the tube from the cover of the inlet for refrigerant then tighten the cover 7 Loose the valve cord of the gas valve as well as the liquid valve entirely 8 Tighten the valve cover of...

Страница 27: ...STOP mode to turn off the unit AUTO STOP Check after installation Items to be checked Has the unit been fixed firmly Have you done the refrigerant leakage test Is the pipe insulation sufficient Does t...

Страница 28: ...the children play with the outdoor unit Never insert any object stick rock sand or others in the unit Never put chemicals products gasoline etc near the outdoor unit during the operation It is recomma...

Страница 29: ...nual 3 Damage to the finish of the unit enclosure or to other outer features caused by wear 4 Filter 5 Damage due to faulty repair and or installation done by a person technician not duly authorized b...

Отзывы: