background image

CARE & ATTENTION

MOVEMENT, TWISTING AND WARPING

Wood contains a natural level of moisture so decreasing humidity levels in the surrounding air may cause panels to change their 

shape as the porous fibres shrink. 

This can be exaggerated during prolonged periods of dry weather.  Movement and gaps in 

timber products are normal. In most cases, the wood will revert to its original form once the high temperatures subside and there is 

more moisture content in the air. Similarly, in winter months, the opposite may occur with the wood swelling.

EXPANSION, CONTRACTION, SPLITS & CRACKS

All timber will expand and contract according to its environment.  As a result of this expansion and contraction, it is very common to 

see splits and cracks developing in the wood.  Splits are common during the spring and summer months as the wood begins to dry 

out. 

The outer surface dries first and contracts over the still expanded core of the wood.  

The result is that splits and cracks appear 

along the grain of the wood. 

These splits are not a fault and do not affect the structural integrity of a product. 

To help you get the most out of our products, it is useful to know a little more about the properties of timber  , what is normal and how your shed may behave  

as the seasons change. Wood is an extremely durable material for construction but, as a natural product, when used outdoors it is susceptible to changes in  

the environment. 

THINGS THAT YOU MIGHT SEE IN YOUR PRODUCT

MOULD & BLUE STAIN

Mould is a surface-dwelling fungus that feeds on nutrients and debris contained in the surface cells of timber. The most common 

problems associated with mould are discolouration of the timber and an increase in permeability of the timber. Blue stain is part of 

the same family but penetrates deeper into the surface layers of the timber. It stains the timber a dark blue colour, whereas mould 

is usually black. These do not cause the timber to rot. Keep the building well ventilated to avoid mould.

 

Treat your building annually. We advise the application of a high quality preservative that contains a mildewcide.  

For more information on the conditions of our guarantee see 

forestgarden.co.uk.

ADVICE ON FELT HANDLING & USAGE

Roof felt is flexible at temperatures above 5°C. In cold temperatures, extra care must be taken when handling and installing to prevent cracking 

and damage to the felt. 

The felt should not be rolled, folded or used in temperatures lower than 5°C. In cold temperatures, the felt should be 

stored indoors above 10°C for 24 hours prior to use. Felt must be lifted, not dragged, and should be stored on its end on a dry surface.

THE ROOF OF THIS BUILDING IS NOT A LOAD BEARING STRUCTURE

8 TOP TIPS TO ENSURE YOUR SHED IS FULLY WATERPROOF

1.    POSITION YOUR SHED IN THE BEST LOCATION IN YOUR GARDEN

Avoid areas where water pools and is constantly wet. Position away from trees and cut back any overhanging foliage which can cause moisture 

to be trapped against shed walls and debris to collect on the roof.

2.   RAISE YOUR SHED OFF THE GROUND

Ideally, any concrete base should be the same footprint as the shed to allow surface water to run off without pooling. A timber shed base can also be 

used. Raise your shed 50mm above ground level.

3.   SEAL THE BEARERS

If using a wooden base, we recommend treating it with a treatment containing wax or oil. Also coat the bearers that come into contact with the ground 

 

4.   USE AN END-GRAIN PROTECTOR

To protect corners and panel joins, an end grain treatment can be applied.

5.   SEAL THE PANELS & WINDOWS

Use a flexible silicon sealant around windows to prevent water ingress. 

This can also be used where two sections of the shed join together . Apply 

 

internally.

6.   CONSIDER ADDING GUTTERS

Adding guttering around the fascia of the shed will redirect rain water away from the shed's foundation.

7.   KEEP VENTILATED

Good airflow around the perimeter of the shed and regular ventilation inside the shed will help prevent mould and mildew

.

8.   CONSIDER A WEATHERPROOFING STAIN OR CLEAR TREATMENT

W

e recommend painting your garden shed with a weatherproofing treatment at least once a year.

 This will help maintain the wood, stabilise timber 

movement and help prolong the life of your garden shed.

TREATED TIMBER CONTAINING A BIOCIDAL PRODUCT

CONTROL OF WOOD DESTROYING ORGANISMS

Active Ingredients 

- Propiconazole, Tebuconazole, IPBC, Permethrine, Benzyl-C12-16-Alkyldimethyl Chlorides. (Dip Treated Sheds)

Basic Copper Carbonate, DDA Carbonate, DDA Chloride. (Pressure Treated Sheds)

Wear gloves when handling. Avoid inhalation of sawdust. Do not get in contact with drinking water or food. Do not use for animal 

bedding or in fish ponds. Dispose of treated wood responsibly

.

to prevent moisture rising.

Содержание TPA46

Страница 1: ...5 00 pm Monday to Friday Fixing Pack TPA46FP 4 x 50mm Screw Qty 30 3 5 x 25mm Screw Qty 41 4 x 45mm Screw Qty 2 3 5 x 30mm Screw Qty 28 Cranked Hinge Qty 2 Felt Tacks Qty 80 T Hinge Qty 2 1 6 x 25mm Nails Qty 16 Casement Stay Qty 1 Rimlock with 50mm screws Qty 1 Door Handle Set with Spindle Qty 1 Escutcheon Qty 1 Lock Receiver Qty 1 4 x 40mm Screw Qty 12 Turn Buttons Qty 2 Qty 2 ...

Страница 2: ... the sections and causing the roof doors and windows to misalign There is more information on base preparation on our website www forestgarden co uk TOOLS NEEDED We recommend using the following tools not supplied Assembly is relatively straightforward if you follow these step by step instructions We recommend aligning components aproperly before securing them together and pre drilling screw holes...

Страница 3: ...old temperatures extra care must be taken when handling and installing to prevent cracking and damage to the felt The felt should not be rolled folded or used in temperatures lower than 5 C In cold temperatures the felt should be stored indoors above 10 C for 24 hours prior to use Felt must be lifted not dragged and should be stored on its end on a dry surface THE ROOF OF THIS BUILDING IS NOT A LO...

Страница 4: ...nnect Walls 2x 50mm Screws Into Bearers under Floor 3x 50mm Screws Into Bearer under Floor Floor Size 1755x1165mm PLACE IN DESIRED LOCATION Plain Side Panel Size 1717x1665mm 3x 50mm Screws Connect Walls 4x 50mm Screws MUST PRE DRILL Barge Boards Size 95x18x760mm Qty 4 95180760PAII66PT Drip Strip Size 28x28x790mm Qty 1 28280790PAII24PT Glazing Strip Large Size 15x12x629mm Qty 2 15120629PAII45PT Gla...

Страница 5: ...FOLD CORNER TACK TRIM OVER HANG 1000 mm OVER LAP FELT 1000 mm 1950 mm 1950x 1000mm 1950x 1000mm Roof Panel Size 1779x710mm Slide into Place Both Sides Panel 5 Window Size 1100x1930mm Cover Strip Size 57x12x1680mm Cover Strip Size 57x12x1680mm Cover Strip Size 57x12x1680mm 4x 30mm Screws 4x 30mm Screws 4x 30mm Screws 4x 30mm Screws Barge Boards Size 95x18x760mm Barge Boards Size 95x18x760mm Barge B...

Страница 6: ...25mm Nails 2x 25mm Screws Step 7 Attaching Drip Strip Step 8 Window Assembly Line up With Battens On Back 2x 25mm Screws 2x 45mm Screws Door Block Size 80x38x140mm 1 Screw through all the way for the block and through the door panel HINGE HINGE Screw the block to the door panel and frame Ensure the hinges are on the opposite side to the block as shown above HINGE HINGE 8mm PLEASE NOTE Ensure there...

Отзывы: