Forest garden Overlap Apex Shed 4x3 Скачать руководство пользователя страница 1

Overlap Apex Shed

4' x 3'' 

Important : 

Assembly of this 

shed requires a 

minimum of two 

adults.

Issue 0115

B

OPA4PE

PLAIN END 

8987658

ROOF SHEET

QTY 2

 

E

 

A

OPA43 PARTS LIST

BRDFL43

FLOOR

SDRPT

DOOR 

OPA4DE

DOOR END 

44121570PT

1570mm C/STRIP QTY 4

H

 K

H

45280866PT

866mm BATTEN QTY 1

F

Place the corner strips so that they cover the joins 
between the panels. Fix each in place using 3 x 30mm 
screws

A

2

4

1

1

C

OPA3PS

PLAIN SIDE 

QTY 2

J

3

REQUIRED TOOLS : 
(NOT SUPPLIED)

POZI DRIVE SCREWDRIVER

SPIRIT LEVEL

TAPE MEASURE

HAMMER

51120810PAII58PT

810mm BARGE BOARD QTY 4

 I

A

Must Pre drill for 
each screw used.

28280898PT

898mm BATTEN QTY 2

 J

FELT 

85062 Qty 1

C

Fixing Pack (OPA43FP)

This fixing pack is used for several products. 
There may be additional fixings.

Not to Scale

Flush Hinge 

Qty 2

50mm Screw Qty 22

30mm Nail Qty 36

25mm Screw Qty 17

Hasp & 

Staple

30mm Screw Qty 17

10mm Felt tacks

 Qty 60

G

FIN20010512PT

FINIAL
 QTY 1

20121695PPT

20 x1695mm STRIP QTY 1

L

A

Fix the 20 x 1695mm strip to the side 
of the door frame so that it is tight 
with the cladding and flush with the 
frame. Use 3 x 30mm screws.

L

SHARP KNIFE

D

Place the hinge against the inside of the door frame and 
position the large section of the hinge so that it is with the 
inside of the framing as shown and fix with 25mm screws.

Open the hinge and fix the smaller section to the door 
framing. Again make sure that the hinge is flush and that the 
holes are positioned so that the 25mm screws locate 
correctly into the batten.

A

B

a

b

E

IMPORTANT, RETAIN FOR FUTURE REFERENCE; READ 

CAREFULLY

This buildings is pressure treated to ensure longevity of all 
timber components and to protect against rot. This may leave 
a colour difference on some parts that will even out as the 
moisture content stabilises. This will not need additional 
treatment.

- This product must be built on a solid level base.
- The roof of this building is not a load bearing structure.
- Please keep all plastic bags and small parts away from 
children.
- Due to the nature of the material the doors may need some 
trimming for a neater fit.
- Timber is a natural material. It will shrink and swell as a 
result of varying moisture content.

Technical Helpline:

 0333 7777 089

  8.30 am and 5.00 

pm  Monday to Friday.

Please check all parts prior to assembly

Assembly of damaged parts may be deemed to be 
acceptance and this may affect the remedies you are entitled 
to. 
If the product is not constructed in accordance with the 
instructions, or is altered in any way (e.g. painted), the 
manufacturer cannot be held liable for any resulting damage.

40mm Screw Qty 12

flush

H

 

Place the 866mm batten so that it connects the door end and plain end. 
Fix this in position using a 50mm screw for each end as shown.

 

 

Place the panels on top of the floor. Make sure that all of the panels are tight and flush before 
fixing them to each other using 3x50mm screws.

Make sure that the panels are sitting flush before fixing to the floor using 2 x 50mm screws for 
each panel. Make sure that all of the screws are positioned so that they screw  in to the bearers 
underneath.

Отзывы: