Foremost FRHI-30S Скачать руководство пользователя страница 37

37

 

 

ADVANCED

 

TROUBLESHOOTING

   

 

Should

 

only

 

be

 

done

 

by

 

trained,

 

certified

 

service

 

professionals

 

Hood

 

insert

 

must

 

be

 

out

 

of

 

wooden

 

hood,

 

down

 

on

 

work

 

surface

 

height,

 

and

 

power

 

cable

 

must

 

be

 

attached

 

with

 

circuit

 

breaker

 

to

 

this

 

power

 

circuit

 

off.

 

 

Fan

 

and

 

Lights

 

will

 

not

 

work

 

at

 

all

 

at

 

any

 

speed

 

or

 

brightness,

 

not

 

responding

 

to

 

control

 

knobs

 

or

 

remote

 

control

 

 

Checking

 

power

 

coming

 

into

 

hood

 

power

 

connection

 

box:

 

Take

 

off

 

wire

 

nuts

 

and

 

place

 

voltmeter

 

across

 

incoming

 

power

 

cable.

 

Turn

 

on

 

circuit

 

breaker,

 

see

 

if

 

house

 

voltage

 

appears

 

(about

 

115

 

to

 

120

 

VAC).

   

If

 

no

 

voltage,

 

check

 

your

 

circuit

 

breaker

 

and

 

wiring

 

to

 

range

 

hood

 

to

 

find

 

the

 

problem.

 

 

Power

 

is

 

detected

 

at

 

hood

 

power

 

connection

 

box:

 

 

Open

 

relay

 

board

 

cover

 

by

 

removing

 

2

 

cover

 

screws.

 

 

If

 

power

 

appears

 

here:

 

 

Check

 

for

 

120

 

volts

 

at

 

these

 

points

 

on

 

the

 

relay

 

board.

 

If

 

power

 

appears

 

here

 

,

 

check

 

for

 

120

 

Volts

 

at

 

other

 

end

 

of

 

fuse

 

and

 

this

 

point.

 

If

 

power

 

does

 

not

 

appear.

 

fuse

 

is

 

blown.

 

Turn

 

circuit

 

breaker

 

off,

 

remove

 

fuse,

 

and

 

check

 

fuse

 

continuity.

 

If

 

fuse

 

is

 

blown,

 

replace

 

with

 

same

 

size

 

(5mm

 

x

 

20

 

mm)

 

and

 

value

 

fuse.

 

For

 

600

 

CFM

 

motor,

 

use

 

8A,

 

for

 

900

 

CFM

 

motor

 

use

 

15A,

 

for

 

dual

 

900

 

CFM

 

motor

 

board,

 

use

 

20

 

Amp

 

slow

 

blow.

 

 

If

 

Power

 

is

 

detected

 

on

 

relay

 

board,

 

but

 

motor

 

will

 

not

 

run

 

at

 

any

 

speed:

   

check

 

motor

 

cable.

 

 

IF

 

MOTOR

 

RUNS

 

AT

 

ALL

 

SPEEDS

 

BUT

 

ONE,

 

 

check

 

and

 

switch

 

motor

 

coil

 

wires

 

shown

 

here

 

(switch

 

A&B,

 

C&D).

 

If

 

switching

 

does

 

not

 

make

 

missing

 

speed

 

work,

 

one

 

speed

 

motor

 

coil

 

is

 

malfunctioning.

 

Return

 

wires

 

to

 

original

 

positions.

 

Replace

 

motor.

 

 

Содержание FRHI-30S

Страница 1: ...English Version Range Hood Inserts Installation Instructions and Operation Manual Models FRHI 30T FRHI 36T FRHI 30S FRHI 36S FRHI 42S FRHI 48S FRHI 42M...

Страница 2: ...ANY PROBLEM 1 DO NOT INSTAll THE UNIT AND KEEP All ORIGINAL PACKAGING MATERIAL 2 Have your original proof of purchase and product serial number ready 3 Contact Foremost Customer Service Toll Free 888...

Страница 3: ...INSTALLATION 13 OPERATING INSTRUCTIONS 26 SPECIFICATIONS 10 MEASUREMENTS DIAGRAMS 12 PARTS LIST 32 TROUBLE SHOOTING 33 WARRANTY 40 WARRANTY INFORMATION FORM 42 READ ALL INSTRUCTIONS CAREFULLY BEFORE S...

Страница 4: ...PA WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low o...

Страница 5: ...you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the ris...

Страница 6: ...quiet because they have precision motors and have many advanced features including super bright LED s a cooking heat sensor non blocking dishwasher safe easy to clean filters and multifunction remote...

Страница 7: ...don t damage anything inside Remove the top Styrofoam pieces Now lay the box on its side make sure the top knobs and pull the two Styrofoam end pieces completely out of the box at the same time Caref...

Страница 8: ...SE TROUGH MOUNTING BRACKET SCREWS MODEL FITER WITH GREASE TROUGH MOUNTING BRACKET 30T 2 2 36T 3 2 Remote control with battery Bag with screws Check entire ventilator unit for damage Check control knob...

Страница 9: ...e from stove top to bottom of wooden hood meets your local fire codes and the range manufacturer s specifications Height of floor to Counter Top A Standard 36 Height of Counter Top to Wood Frame Botto...

Страница 10: ...rect It is assumed the correct Foremost Range Hood Insert was selected based on the selection guide for the wooden hood brand name and size chosen for your kitchen For M S type units mounted in Chimne...

Страница 11: ...tle Hood must have 1 inch thick or greater side beams to support weight and mounting of hood insert The following are tables of the overall dimensions of all the models of Foremost Range Hood Inserts...

Страница 12: ...12...

Страница 13: ...ghly recommended carry and place the range hood insert into pre mounting position underneath wooden hood NEVER PLACE THE INSERT FACE DOWN WITHOUT WOODEN BLOCKS HOLD IT 2 INCHES ABOVE THE BOTTOM SURFAC...

Страница 14: ...n if not ignore this step Close the cover on the connection box In order to comply with some local building codes this unit has been shipped with the maximum exhaust speeds shut off If these codes do...

Страница 15: ...jumper shown in OFF position Exhaust fan will now run at all speeds including Maximum Carefully PULL IT OFF AND DISCARD or place it back in the OFF position shown Now the range insert will run at ful...

Страница 16: ...ATE REFER TO THE ADVANCED TROUBLESHOOTING SECTION AT THE END OF THIS VIDEO Turn the knob again to the right clockwise There will be another beep and the fan will go to the second speed Turn the knob a...

Страница 17: ...se results please CONTACT FOREMOST CUSTOMER SERVICE IMMEDIATELY TEST THE REMOTE CONTROL Locate the bag containing the remote control and battery Carefully open the battery door on the back of the remo...

Страница 18: ...d light setting you set in the memory button To change the setting set the lights and fan to where you want then repeat the press and hold procedure until you hear a beep If the remote control does no...

Страница 19: ...t Electric drill with screwdriver bit installed highly recommended or a screwdriver Ducting prepared and vent openings prepared and ready Below are the three types of ducting Exhaust out roof vent Exh...

Страница 20: ...rt at this time Lift the hood insert up into the prepared opening feeding the power cable up with it being careful not to pinch the cable Raise the hood to the desired height If it goes in smoothly wi...

Страница 21: ...rear mounting screw into block Wooden block or rail secured to rear wall for holding up rear end of adapter extension While holding the hood insert in place at the proper mounting height screw in two...

Страница 22: ...ou should not be able to push the filter up This will prevent the filter from being lifted up by the fan at high speeds How to grab baffle filter for removal or installation Insert Baffle Filter and s...

Страница 23: ...binet to secure the unit Make sure the unit has been connected to power and was thoroughly tested procedure listed on page xx in an earlier section of the manual and ductwork is prepared Turn off circ...

Страница 24: ...THE FRONT AND BACK POINT Carefully Lower the hood insert back to the stove surface keeping the knobs from touching using the stand off blocks Remove the side mounting brackets by removing the screws...

Страница 25: ...rackets from the inside of the hood using the screws supplied Connect remaining ductwork Insert grease troughs and baffle filters sliding them forward and then seating them back into the grease trough...

Страница 26: ...position The lights will also turn on to the night light position This the lowest and most quiet fan speed and perfect for light cooking Turn the knob again to the right There will be another beep an...

Страница 27: ...n to the right The light will light will raise one level brighter to the maximum brightness To lower the brightness turn the light knob quickly to the left counterclockwise The light will drop one lev...

Страница 28: ...an goes to speed 3 Press the UP ARROW again You will hear a beep The fan goes to speed 4 max speed If you have a model 48S you can press one more time to get speed 5 Now let s lower the speed Press th...

Страница 29: ...n press and hold the MEMORY button until you hear a beep from the unit This setting has now been memorized Press the RED POWER OFF Button and the unit will shut completely off Now press the MEMORY but...

Страница 30: ...crewing the thumbscrews on the inside as shown Place the filters in a dishwasher for cleaning along with the grease troughs Re assemble baffle filters and replace in hood sliding them in from the back...

Страница 31: ...OR CLOTHS or steel wool to clean the range hood insert Use only mild soap or detergent solutions on a damp rag to clean around edges and control panel knobs lights and heat sensor Dry surfaces using...

Страница 32: ...JUNCTION BOX COVER 14 SIDE BRACKET ONLY FOR 30T AND 36T 4 JUNCTION BOX 15 LED 5 RELAY BOARD 16 ANTENNA BOARD 6 MOTOR BOX 17 ENCODER BOARD COVER 7 RELAY BOARD COVER 18 HIGH TEMPERATURE SENSOR 8 MOTOR...

Страница 33: ...is there call FOREMOST to be sent an replacement LED assembly If voltage not there call Foremost to be sent a replacement control board Fan motor runs but will not run at highest speeds 3 4 or extra s...

Страница 34: ...and carefully reposition grease troughs and filters re hook filters to front inside surface of hood body on 900 CFM units Make sure filters are secured together tightly with thumb screws on back Remo...

Страница 35: ...d the control panel as you do this as it will drop and be attached to wires when you do this Locate the cover on the back that houses the circuit board Carefully remove the 2 screws holding it on with...

Страница 36: ...carefully keeping the wires in place and not letting them get pinched or intrude into the baffle filter area Turn on circuit breaker powering this unit If you did the following steps correctly the re...

Страница 37: ...is detected at hood power connection box Open relay board cover by removing 2 cover screws If power appears here Check for 120 volts at these points on the relay board If power appears here check for...

Страница 38: ...trol If there is still no motor or Light response CALL FOREMOST CUSTOMER SERVICE to order a replacement control board Makeup Air System not getting power signal above speeds 1 2 If 120 Volts is not de...

Страница 39: ...39 Typical Make up air system diagram with motorized inlet damper...

Страница 40: ...ranty period additional charges may apply which include but are not limited to Parts shipping expenses Un installation of defective product and Installation of replacement product It is your sole resp...