Mounting
The Sirius F80 and F80P are designed to be mounted on top of a 80mm junction box.
Pull the cable through the mounting plate.
Mount the back plate using two screws.
Connect cable to the 7-pin screw connector.
Remove the thin orange film from the buzzer.
Attach the top of the reader to the back plate and push the bottom towards the back plate
Close the reader using the enclosed 3mm screws.
Wiring
You can use a standard CAT5 UTP or CAT6 UTP network cable with RJ45 T-568B
connectors to connect the card reader to the Polyx NF+.
Plug the RJ45 connector of one end of the cable in port Reader 1 or Reader 2 of the Polyx
NF+.
Cut off the RJ45 from the other end of the network cable.
Remove the isolation and untwist the wires.
Combine the orange and green wires and connect them to pin 1 (A).
Combine the white/orange and white/green wires and connect them to pin 2 (B).
Connect the brown wire to pin 6 (GND).
Connect the blue wire to pin 7 (VCC+).
The white/brown and white/blue wire are not used.
Sirius F80
RJ45 T568B color
RJ45 T568B pin
7 VCC (+)
Blue
4
Brown
8
5