Version 2.0
- CFR power On boot-up fails, attempt to recover the
software, on the VCM II and retry, (refer to
IDS User
Manual
).
•
If VCM II - CFR fails to power On after making all the
checks above, contact your regional technical support
VCM II - CFR powers On, but
operates abnormally
•
Cycle (remove/reconnect) power to the VCM II - CFR
•
Make sure that the VCM II - CFR performs the power
On boot-up successfully.
•
If the VCM II - CFR power On boot-up fails, attempt
to recover the software on the device and retry power
On boot-up.
•
If the VCM II - CFR power On boot-up problem
persists, contact your regional technical support
VCM II - CFR Power LED is on,
but no 1 second beep
•
USB issue. Attempt to recover the software on the
VCM II – CFR, (refer to
IDS User Manual
).
•
If VCM II - CFR error persists, contact your regional
technical support
VCM II - CFR Error LED is red
immediately after it is booted
•
Reboot the PC
•
Attempt to recover the software, on the VCM II – CFR,
(refer to
IDS User Manual
).
•
Restart the Firmware Update Process
•
Attempt a recovery on a different PC (may be a PC
related issue)
•
If the VCM II - CFR boot-up problem persists, contact
your regional technical support
VCM II - CFR Error LED blinks
and Speaker beeps for 15
seconds, and Power LED is
illuminated
•
Prior firmware update failure. Attempt to recover the
software on the VCM II, (refer to
IDS User Manual
).
•
If VCM II - CFR error persists after making the check
above, contact your regional technical support
VCM II - CFR PC Interface LED
blinks and speaker beeps at a
periodic rate after a power cycle,
and the Power LED is illuminated
•
Contact your regional technical support. (SD-Card is
corrupt/damaged and needs to be re-initialized by the
manufacturer)
VCM II - CFR turns off (shuts-
down/suspends-operation, all
LEDs off) immediately after
being powered by the USB cable
or DLC cable
•
Verify the ambient temperature is within the acceptable
operating range for the VCM II - CFR device: -20°C to
70°C (-4°F to 158°F)
•
If the ambient temperature is outside this range allow
the temperature to return to the acceptable operating
range and the VCM II – CFR will automatically
resume operation
•
If VCM II – CFR error persists when the ambient
temperature returns to its operating range, contact your
regional technical support
VCM II - CFR will not Wake up
from Sleep Mode
On certain vehicle applications the VCM II - CFR may not
automatically wake up when the ignition key is turned to
the ON or RUN position. If this should happen, press the
Trigger button on the end of the Pendant to wake up the
VCM II - CFR. The VCM II - CFR will then attempt to
establish communication with the vehicle. If the VCM II -
CFR is unable to establish communications with the
vehicle, it will go back to sleep after approximately 60