Ford F2E425E891 Скачать руководство пользователя страница 5

5

SAFETY RULES

• Do not wear loose clothing or gloves.

• Remove jewelry or anything else that could be caught in moving parts.

• Tie back or wear protective head covering to contain long hair.

WARNING!

Starter and other moving parts can catch on clothing, jewelry, and hair.

Keep engine away from flammable objects and other hazardous materials.

death.

The fuel and its vapors used to power this unit are highly flammable and could explode resulting in serious injury or

Never fill or drain fuel tank indoors.

Never overfill fuel tank.  If fuel spills, move the unit at least 30 feet away from the spill and wipe up any remaining fuel

on the unit before starting the engine.

• Never smoke while operating or fueling this unit.

Never operate or store this unit near an open flame, heat, or any other ignition source.

• Generator should have at least 5 feet of clearance from buildings or other equipment during operation.

Keep engine free of grass, leaves, or grease which are flammable.

• When adding or draining fuel, unit should be turned off for at least 2 minutes to cool before removing fuel cap.  If unit

has been running then the fuel cap is under pressure, remove slowly.

• To keep fuel from spilling, secure unit so it cannot tip while operating or transporting.

• When transporting unit, disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff valve

turned to the off position.

WARNING!

Never exceed generator’s wattage / amperage capacity.  This could damage the generator 

and / or connected electrical devices.

WARNING!

Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator.

• To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly.

WARNING!

Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which

could result in injury.

• Always start the engine and let it stabilize before connecting any electronic devices.

• Disconnect all electronic devices before stopping the engine.

WARNING!

Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do

so could damage the generator and / or connected electrical devices.

• Allow hot components to cool before touching.

Use caution around the muffler, cylinder, and other engine parts as they can be extremely hot.

WARNING!

Avoid contacting hot areas of this unit.

Содержание F2E425E891

Страница 1: ...ordpower cc OPERATOR S MANUAL MODEL FG5250PBR ITEM F2E425E891 Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other re...

Страница 2: ...d Generator 16 Wattage Reference Guide 16 Cold Weather Operation 17 Maintenance 18 Maintenance Schedule 18 Engine Maintenance 18 Changing Oil 19 Maintaining Fuel Valve 21 How to Store 22 Troubleshooti...

Страница 3: ...rranty assistance or other services inquiries you can contact us by internet at www fordpower cc The emissions control system for this generator is compliant with all standards set by the U S Agency R...

Страница 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...

Страница 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...

Страница 6: ...nerator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to prevent electrocution Never handle the...

Страница 7: ...r C Circuit Protector D Voltage Selector Switch E 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 A B E F Hour Meter G 120 V duplex Receptacle NEMA 5 20R H 120 Volt AC 30 Amp RV receptacle TT...

Страница 8: ...Vent M Generator Frame N Choke Lever O Air Filter P Handles Grips Q Regulator L S R Support Leg Foot S Fuel Tank T Fuel Fill Cap U Fuel Valve ON OFF V Recoil Starter Grip W Oil Fill Dipstick X No Flat...

Страница 9: ...r 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Qty Generator 1 Quick...

Страница 10: ...ping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame Secure the wheel assembly by reinserting a ha...

Страница 11: ...urface wipe dipstick clean then reinsert dipstick without rethreading Adding Checking Engine Oil See fig 6 You must add oil before first operating this generator Always check oil level before each ope...

Страница 12: ...ous injury or death to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to...

Страница 13: ...oil handle starter cord slowly until resistance is felt then pull rapidly See fig 14 For remote start press remote control to START position See fig 15 Let engine run for several seconds and then grad...

Страница 14: ...ee fig 20 2 Press remote control to STOP position See fig 21 only remote start 3 Close LPG Tank See fig 19 Receptacles and Extension Cords Only use high quality well insulated grounded extension cords...

Страница 15: ...to the below table to ensure the extension cord used has the capacity to carry the required load If the size of the cable is inadequate it can cause a voltage drop which can damage the electrical devi...

Страница 16: ...Surge Watts 75W Light Bulbs 75 each 75 each 18 CU Ft Refrigerator Freezer 800 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifie...

Страница 17: ...is needed The display will show the word LUBE at the first 25 hours of operation and again at every 100 hours of operation after Never exceed generator s wattage amperage capacity This could damage th...

Страница 18: ...Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level Annually 25 hr Use Check and Clean Air Cleaner Change Engine Oil S...

Страница 19: ...res determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Carefully add SAE 10W 30 to empty reservoir until the oil re...

Страница 20: ...emove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter annually Reinstall ai...

Страница 21: ...empty if needed or inspect filter prior to fill up CAUTION Draining Fuel Tank and Carburetor To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing...

Страница 22: ...stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor Store the generator indoors to prevent freezing The generator must be Shipped Run and Stored in th...

Страница 23: ...6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Engine has...

Страница 24: ...DIAGRAMS 24...

Страница 25: ...coverage on generator engine and alternator components parts only 24 Month Limited coverage on generator engine components parts only Personal use means personal residential household use or recreati...

Страница 26: ...r mail the original receipt and product to the address found on the web site if purchased on line You can also locate your nearest Ford Power Equipment dealer for service or warranty questions by call...

Отзывы: