WARRANTY

25

Ford Power Equipment Limited 2 Year Warranty:

From the date of original purchase, Ford Power Equipment warrants to the original purchaser that each portable generator 

sold, shall be free from defect in material and workmanship for the items and time period set forth below. Ford Power 

Equipment, at its discretion, agrees to repair or replace any defective part that upon examination, inspection, and testing by 

a Ford Power Equipment authorized service dealer, is found to be defective within the original warranty period. Ford Power 

Equipment will also decide upon the use of new or rebuilt parts or comparable product. Any part or product that is replaced 

will be retained by Ford Power Equipment. This warranty period shall not be extended and any repaired product shall be 

warranted for the remaining period of the original warranty. The consumer is responsible, and shall prepay all transportation 

costs, including returning items to the factory or warehouse. This warranty is non-transferable and  proof of purchase must 

be presented for requesting warranty service. If a proof-of-purchase receipt is not provided, the product’s shipping date by 

the manufacturer will be used to determine the warranty period.

Length of Warranty:

P

ers

on

al use applicati

on

of

 this p

o

rtable 

g

e

n

erat

o

r are 

w

arra

n

te

d

 

fo

24

 

mon

th 

o

500

 hrs usi

ng

 

(

Whiche

v

er 

c

om

es 

f

irst). 

P

r

oof

 

of

 purchase a

nd

 

ofm

ai

n

te

n

a

n

ce 

m

ust be pr

ov

i

d

e

d

.

6 Month - Limited comprehensive coverage on all generator components and labor.

12 Month - Limited coverage on generator engine and alternator components, parts only.

24 Month - Limited coverage on generator engine components, parts only.

“Personal use” means personal residential household use or recreational use by the retail consumer. “Commercial use” 

means all other uses including commercial, construction, or other income producing purposes. Once a generator has been 

used for commercial purposes, it shall thereafter be considered as a “commercial use” generator for the purposes of this 

warranty. Any portable generator used for commercial use, as rental equipment or for the purpose of primary power in place 

of utility, will not be covered under this warranty.

Consumer Responsibilities:

Consumer is responsible for carefully reading and following all instructions in the owner’s manual. Any product that is 

damaged due to misuse or abuse will not be covered by this warranty.

Consumer is responsible for all transportation costs to an authorized Ford Power Equipment Service Center. Unless 

otherwise requested, ground shipping will be applied for part shipment and customer will pay any additional charges for 

expedited shipments.

Consumer is responsible for labor costs associated with warranted repairs twelve (12) months after the purchase date.  

Consumer is responsible for maintaining generator as specified in the owner’s manual. Documentation of this

Labor rates will only be based on normal working hours. 

maintenance may be required to cover warranty requests.

Consumer is responsible for presenting any problems with the generator to an authorized Ford Power Equipment 

Service Center as soon as the problem exists. Warranted repairs will be completed in a reasonable period of time, not 

to exceed 30 days.

Содержание F2E300R991

Страница 1: ...fordpower cc OPERATOR S MANUAL MODEL FG4050P ITEM F2E300R991 Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other rep...

Страница 2: ...Adding Fuel 11 Connecting Generator to an Electrical System 12 Operation 13 How to Start Engine 14 Grounding the Generator 13 How to Stop Engine 14 Receptacles and Extension Cords 14 Don t Overload G...

Страница 3: ...cations To order parts receive warranty assistance or other services inquiries you can contact us by internet at www fordpower cc The emissions control system for this generator is compliant with all...

Страница 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...

Страница 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...

Страница 6: ...nerator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to prevent electrocution Never handle the...

Страница 7: ...RES A ON OFF Switch B Main Circuit Breaker C Circuit Protectors D Voltage Selector Switch A B E E Hour Meter F 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 G 120 V duplex Receptacle 5 20R...

Страница 8: ...t J Generator Frame K Choke Lever L Air Filter M Handles Grips N Oil Drain Plug O Support Leg Foot P Fuel Tank Q Fuel Fill Cap R Fuel Valve ON OFF T Oil Fill Dipstick U No Flat Foam Filled Tires I P Q...

Страница 9: ...ting the generator 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Qty G...

Страница 10: ...ping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame Secure the wheel assembly by reinserting a ha...

Страница 11: ...urface wipe dipstick clean then reinsert dipstick without rethreading Adding Checking Engine Oil See fig 6 You must add oil before first operating this generator Always check oil level before each ope...

Страница 12: ...r back up power notify the utility company If connecting generator to a building s electrical system for standby power you must use a qualified electrician to install a transfer switch Failure to isol...

Страница 13: ...he choke is fully slid to the RUN position See fig 12 How to Start Engine See fig 9 12 Slide the choke lever to the Choke position See fig 10 SKIP THIS IF THE ENGINE IS WARM OR HOT Fig 9 Fig 11 Recoil...

Страница 14: ...ne ON OFF switch to the OFF position Receptacles and Extension Cords Only use high quality well insulated grounded extension cords in good condition with generator receptacles Follow each load manufac...

Страница 15: ...ow table to ensure the extension cord used has the capacity to carry the required load If the size of the cable is inadequate it can cause a voltage drop which can damage the electrical device and cor...

Страница 16: ...Surge Watts 75W Light Bulbs 75 each 75 each 18 CU Ft Refrigerator Freezer 800 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifie...

Страница 17: ...il See page 19 Check oil daily or after every 8 hours of use 3 Turn fuel valve to the open position 4 Ensure generator is serviced according to the maintenance schedule under Maintenance section of ma...

Страница 18: ...Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level Annually 25 hr Use Check and Clean Air Cleaner Change Engine Oil S...

Страница 19: ...res determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Carefully add SAE 10W 30 to empty reservoir until the oil re...

Страница 20: ...Equivalent To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter...

Страница 21: ...empty if needed or inspect filter prior to fill up CAUTION Draining Fuel Tank and Carburetor To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing...

Страница 22: ...stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor Store the generator indoors to prevent freezing The generator must be Shipped Run and Stored in th...

Страница 23: ...6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Engine has...

Страница 24: ...DIAGRAMS 24...

Страница 25: ...coverage on generator engine and alternator components parts only 24 Month Limited coverage on generator engine components parts only Personal use means personal residential household use or recreati...

Страница 26: ...l the original receipt and product to the address found on the web site if purchased on line You can also locate your nearest Ford Power Equipment dealer for service or warranty questions by calling t...