Note:
The service disconnect has an outer
lever to aid in the proper seating of the
service disconnect lever. Remove this to
disconnect the high-voltage service
disconnect.
The high-voltage service disconnect is
located behind the rear fold down seats.
Service disconnect location for non-Energi
vehicles.
E163537
Service disconnect location for Energi
vehicles.
E163538
Disabling the High-Voltage Battery
1.
Fold down the rear seats and remove
the cover panel.
2. Locate the access door and remove
the plastic cover.
E171514
3. Pull the outer cover off to expose the
service disconnect lever.
E147234
4. Slide the handle on the service
disconnect outboard to the right. For
Energi vehicles, slide the handle
outboard and to the left.
E146133