![Ford 2008 Escape Hybrid Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/ford/2008-escape-hybrid/2008-escape-hybrid_emergency-response-manual_2317782010.webp)
FCS-14265-08
10
High-Voltage Service Disconnect Switch Shown in LOCK position.
High-voltage system is STILL ACTIVE.
Remove switch and place in SERVICE/SHIPPING position
to disconnect high-voltage system.
WARNING
•
Removing the high-voltage service disconnect switch
disconnects high voltage from the vehicle.
•
The individual cells inside the battery pack will still be charged.
•
Do not cut into the high-voltage battery case or penetrate the
batteries in any way.