![Ford 1999 Mustang Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/ford/1999-mustang/1999-mustang_workshop-manual_2317422026.webp)
Generator C154
Connect a fused (5A) jumper wire between generator C154, Circuit 904 (LG/RD), harness side and ground.
Does the charge system indicator illuminate?
Yes
INSTALL a new generator; REFER to
Section 414-02
. CLEAR the DTCs. REPEAT the self-test.
No
GO to
M4
.
M4
CHECK CIRCUIT 904 (LG/RD) FOR OPEN
Instrument Cluster C250
Measure the resistance between instrument cluster C250 Pin 5, Circuit 904 (LG/RD), harness side and
generator C154, Circuit 904 (LG/RD), harness side.
Is the resistance less than 5 ohms?
Yes
INSTALL a new instrument cluster; REFER to
Instrument Cluster
. CLEAR the DTCs. REPEAT the self-test.
No
REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.
M5
CHECK THE GENERATOR
Generator C154
Does the charge system indicator illuminate?
Yes
GO to
M6
.
Page 26 of 32
1999 Mustang Workshop Manual
1/18/2013
http://www.fordtechservice.dealerconnection.com/pubs/content/~WSXB/~MUS~LEN/20/...