7 Warranty

 

 The limited warranty that applies to AeroCollect

®

 will be null and void if the 

following is not complied with:

The device and sampling chambers must not be exposed to violent knocks or impacts 

The AeroCollect

®

 device and sampling chambers must not under any circumstances be 

immersed in water or any other liquid and must be stored in the accompanying case so as to 
be protected from moisture during those periods when not in use.  

Cleaning and disinfection must be carried out in accordance with the associated section in 
this manual. 

The AeroCollect

®

 device must not be dismantled. 

 
When shipping the device, it must be sent in the accompanying case.  

If the AeroCollect

®

 device stops working, regardless of the reason, immediately 

contact AeroCollect for the purpose of determining the cause of the malfunction. 
See below for contact details. 

Technical specifications

8.1 Battery

AeroCollect

®

 is powered by two AA batteries. These may be single use or 

rechargeable batteries and they must be disposed of in accordance with the 
manufacture’s instructions

8.2  

Expected battery lifetime

The AeroCollect

®

 device is capable of collecting samples for a minimum of 

two concecutive hours using two fully-charged batteries.

8.3 

Operating environment

8.3.1  Recommended temperatures for AeroCollect

®

:

 

 Storage temperature range:  

-20ºC to +40ºC

 

Transport temperature range:  

-40ºC to +60ºC

 

Normal use temperature range:  

-20ºC to +40ºC

Содержание AeroCollect

Страница 1: ...User Manual...

Страница 2: ...owever whenever the device is not being used it should be stored in the accompanying protective suitcase 2 Before you start First check that all of the parts are in the case see section 2 1 If some th...

Страница 3: ...se contents 2 2 Overview of equipment Rear Front On Off Model Nr 000 Serie Nr 0000 FORCE Technology Venlighedsvej 4 2970 H rsholm WEEE CE mark Batteries 2 x AA Air out Sampling Green LED Wait Error Re...

Страница 4: ...the sample chamber in the device is given below 1 Open the protective tube and take out the sample chamber The sample chambers are supplied in a protective tube which can easily be disinfected on the...

Страница 5: ...it in the meantime The process should take less than 1 second 7 At 400 V the pump will start and the sampling procedure will be initiated which will be indicated by the green LED being lit while the r...

Страница 6: ...ing Refer to the contact information at the end of this manual 4 2 Replacement of batteries AeroCollect is powered by two AA batteries The batteries are easy to replace Simply open the cover on the ba...

Страница 7: ...cedure can be used to check if the sample chamber is blocked If the chamber is blocked the sound of the pump will not change either 4 5 Disinfection of AeroCollect Both the AeroCollect device and its...

Страница 8: ...be too low and unable to power the pump If the batteries are drained of power and therefore cannot power the pump the pump will not start and the green LED will remain unlit and the red LED will remai...

Страница 9: ...he device it must be sent in the accompanying case If the AeroCollect device stops working regardless of the reason immediately contact AeroCollect for the purpose of determining the cause of the malf...

Страница 10: ...0 C Transport of collected samples temperature range 80 C to 30 C Normal use temperature range 20 C to 40 C 8 3 4 Recommended air humidity for sample chamber Transport and storage air humidity range 3...

Страница 11: ...9 Contact information For more information about the use of AeroCollect contact FORCE Technology AeroCollect Venlighedsvej 4 2970 H rsholm Denmark Tel 45 43 25 14 00 aerocollect force dk...

Страница 12: ...5098 3 EN FORCE Technology AeroCollect Venlighedsvej 4 2970 H rsholm Denmark Tel 45 43 25 14 00 aerocollect force dk aerocollect dk...

Отзывы: