Force Logic LOAD-MASTER LITE Скачать руководство пользователя страница 2

 

KEY FUNCTIONS

 

 

ON/OFF

 

 

 

Press and hold ON/OFF for approximately 2   

 

 

 

 

seconds. Display shows software version, then 

 

 

 

'BUSY' while unit acquires radio signal from load 

 

 

 

cell.

 

 

 

 

Live reading will now be displayed. Press and 

 

 

 

 

hold to switch off.

 

 

 

 

(Auto switch

-

off after 20 mins. of no activity)

 

 

TARE

 

 

Press to select NET/GROSS value. On start

-

up 

 

 

 

the display will show previously used setting 

 

 

 

 

(GROSS, or previous NET value). Gross weight is 

 

 

 

indicated when is arrow above 'G'. Net weight is 

 

 

 

indicated when arrow is above 'NET'.

 

 

PEAK HOLD

 

Press to display only maximum measured load.

 

 

 

 

Display flashes while in PEAK mode.

 

 

 

 

Press again to return to live reading mode.

 

 

 

WARNING INDICATIONS

 

 

SIG LOW

 

Indicated when unit is out of range, or not line 

 

 

 

of sight. Signal strength will be affected by   

 

 

 

 

battery life.

 

 

BATT LOW

’ 

 

Indicates low battery condition. Displayed when 

 

 

 

battery voltage drops below 2.4V

 

 

 

 

Separate indication for handset & load cell.

 

 

ERROR

 

  

 

Indicated when the radio transmitter is not     

 

 

 

receiving a signal from the load cell. In this 

 

 

 

 

case, contact supplier for service.

 

 

OVERLOAD

’ 

 

Indicated when load cell rated capacity is       

 

 

 

exceeded by 2%

 

 

(If overload occurs, do not use load cell and return 

to supplier for inspection and calibration )

 

 

Yearly inspection and re

-

calibration is advised to ensure correct 

operation and safe use.

 