![Force Logic LOAD-MASTER LITE Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/force-logic/load-master-lite/load-master-lite_user-manual_2317049002.webp)
KEY FUNCTIONS
ON/OFF
Press and hold ON/OFF for approximately 2
seconds. Display shows software version, then
'BUSY' while unit acquires radio signal from load
cell.
Live reading will now be displayed. Press and
hold to switch off.
(Auto switch
-
off after 20 mins. of no activity)
TARE
Press to select NET/GROSS value. On start
-
up
the display will show previously used setting
(GROSS, or previous NET value). Gross weight is
indicated when is arrow above 'G'. Net weight is
indicated when arrow is above 'NET'.
PEAK HOLD
Press to display only maximum measured load.
Display flashes while in PEAK mode.
Press again to return to live reading mode.
WARNING INDICATIONS
‘
SIG LOW
’
Indicated when unit is out of range, or not line
of sight. Signal strength will be affected by
battery life.
‘
BATT LOW
’
Indicates low battery condition. Displayed when
battery voltage drops below 2.4V
Separate indication for handset & load cell.
‘
ERROR
’
Indicated when the radio transmitter is not
receiving a signal from the load cell. In this
case, contact supplier for service.
‘
OVERLOAD
’
Indicated when load cell rated capacity is
exceeded by 2%
(If overload occurs, do not use load cell and return
to supplier for inspection and calibration )
Yearly inspection and re
-
calibration is advised to ensure correct
operation and safe use.